Home › Engine / Hybrid System › 1GR-FE (STARTING) › RELAY
RM38G0E _51 Engine / Hybrid System _101534 1GR-FE STARTING _0470529 RELAY G

1GR-FE STARTING  RELAY  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 28300 1.INSPECT STARTER RELAY (ST NO. 1)

a.
A413846N06
2.271,0.698 2.552,0.594 false 2.719,0.854 3,0.75 false 2.313,1.417 2.573,1.25 false 2.688,1.5 2.958,1.333 false 0.292,0.667 0.448,0.865 0.156,0.198 10 false 3 0.271,1.375 0.427,1.573 0.156,0.198 10 false 1 1.563,1.375 1.719,1.573 0.156,0.198 10 false 2 1.563,0.677 1.719,0.875 0.156,0.198 10 false 5 2.594,0.469 2.75,0.667 0.156,0.198 10 false 1 2.604,0.792 2.76,0.99 0.156,0.198 10 false 2 2.198,1.354 2.354,1.552 0.156,0.198 10 false 5 3.01,1.219 3.167,1.417 0.156,0.198 10 false 3

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the starter relay.