Home › Engine / Hybrid System › V35A-FTS (COOLING) › THERMOSTAT
RM38G0E _51 Engine / Hybrid System _101529 V35A-FTS COOLING _0473312 THERMOSTAT G

V35A-FTS COOLING  THERMOSTAT  INSPECTION  


PROCEDURE

Hide 16031 1.INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT

HINT:
A489691

The valve opening temperature is inscribed on the thermostat.


a.

Immerse the thermostat in the water, then heat the water gradually.

CAUTION:
A342307

·

Do not your hands into the water that has been heated for the inspection.

·

Touching the heated water could result in burns.




b.

Check the valve opening temperature of the thermostat.

Standard valve opening temperature:

80 to 84°C (176 to 183°F)


If the valve opening temperature is not within the specified range, replace the thermostat.


c.
A489692C01
2.99,1.625 3.302,1.781 0.313,0.156 10 false *a
*a Valve Lift


Check the valve lift.

Standard valve lift:

8 mm (0.315 in.) or more at 95°C (203°F)


If the valve lift is not as specified, replace the thermostat.


d.

Check that the valve is fully closed when the thermostat is below 72 °C (162 °F)

If the valve is not fully closed, replace the thermostat.