Home › General › SPECIFICATIONS › V35A-FTS INTAKE / EXHAUST
RM38G0E _V1 General _100727 SPECIFICATIONS _0478820 V35A-FTS INTAKE / EXHAUST F

SPECIFICATIONS  V35A-FTS INTAKE / EXHAUST  SERVICE DATA  


COOLANT
Standard Capacity Classification
3.8 liters (4.0 US qts, 3.3 Imp. qts) TOYOTA vehicles are filled with TOYOTA SLLC at the factory. In order to avoid damage to the engine cooling system and other technical problems, only use TOYOTA SLLC or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology consists of a combination of low phosphates and organic acids).

INTAKE AIR CONTROL VALVE
Air by-pass valve assembly Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 8.6 to 9.6 Ω

TURBOCHARGER
Turbocharging pressure Standard pressure 90 kPa or higher (0.9 kgf/cm2, 13 psi)
Turbine with valve housing sub-assembly Warpage Standard 0.20 mm (0.00787 in.)
Waste gate valve Clearance Standard 0.50 mm (0.0197 in.)
Axial play of turbine shaft Standard 0.10 mm (0.00394 in.) or less

Waste gate valve control actuator Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 1 to 100 Ω

RESERVE TANK CAP (for Intercooler)
Item Specified Condition
Standard value (for brand-new cap) 93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi)
Minimum standard value (for used cap) 79 kPa (0.8 kgf/cm2, 11.4 psi)

EXHAUST PIPE
Compression spring Minimum free length Front and center exhaust pipe side 43 mm (1.69 in.)
Tail exhaust pipe side 42 mm (1.65 in.)