16331A 1.INSPECT THERMOSTAT
Do not your hands into the water that has been heated for the inspection.
Touching the heated water could result in burns.
The valve opening temperature is inscribed on the thermostat.
Immerse the thermostat in the water, then heat the water gradually.
Check the valve opening temperature of the thermostat.
74 to 78 °C (165 to 172 °F)
If the valve opening temperature is not within the specified range, replace the thermostat.
| *a | Valve Lift |
Check the valve lift.
10 mm (0.394 in.) or more at 90 °C (194 °F)
13.3 mm (0.524 in.) or less at 120 °C (248 °F)
If the valve lift is not as specified, replace the thermostat.
Check that the valve is fully closed when the thermostat is below 71 °C (160 °F)
If the valve is not fully closed, replace the thermostat.