Home › Engine / Hybrid System › F33A-FTV (COOLING) › THERMOSTAT › from 2021.07
RM38G0E _51 Engine / Hybrid System _106334 F33A-FTV COOLING _0484472 THERMOSTAT G

F33A-FTV COOLING  THERMOSTAT  INSPECTION  


PROCEDURE

Hide 16331A 1.INSPECT THERMOSTAT

CAUTION:
A342307

·

Do not your hands into the water that has been heated for the inspection.

·

Touching the heated water could result in burns.



HINT:
A493688

The valve opening temperature is inscribed on the thermostat.


a.

Immerse the thermostat in the water, then heat the water gradually.


b.

Check the valve opening temperature of the thermostat.

Standard valve opening temperature:

74 to 78 °C (165 to 172 °F)


If the valve opening temperature is not within the specified range, replace the thermostat.


c.
A493689C02
2.74,1.802 3.052,1.958 0.313,0.156 10 false *a
*a Valve Lift


Check the valve lift.

Standard valve lift:

10 mm (0.394 in.) or more at 90 °C (194 °F)

13.3 mm (0.524 in.) or less at 120 °C (248 °F)


If the valve lift is not as specified, replace the thermostat.


d.

Check that the valve is fully closed when the thermostat is below 71 °C (160 °F)

If the valve is not fully closed, replace the thermostat.