| Condition | Specified Condition |
|---|---|
| Standard valve opening temperature | 74 to 78 °C (165 to 172 °F) |
| Standard valve lift | 10 mm (0.394 in.) or more at 90 °C (194 °F) |
| 13.3 mm (0.524 in.) or less at 120 °C (248 °F) |
| Item | Tester Connection | Condition | Specified Condition |
|---|---|---|---|
| Reserve tank cap | - | Standard pressure (for brand-new reserve tank cap) |
94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 17 psi) |
| - | Minimum standard pressure (for used reserve tank cap) |
79 kPa (0.8 kgf/cm2, 11.5 psi) | |
| Fluid coupling assembly | 1(EFC+) - 3(GDFC) | 20°C (68°F) | 7.05 to 8.61 Ω |