Home › Vehicle Interior › HEATING / AIR CONDITIONING › RELAY › from 2021.07
RM38G0E _58 Vehicle Interior _100766 HEATING / AIR CONDITIONING _0467932 RELAY G

HEATING / AIR CONDITIONING  RELAY  INSPECTION  


PROCEDURE

Hide 1.INSPECT PTC HEATER RELAY(PTC_NO. 1, PTC_NO. 2, PTC_NO. 3)

a.
E374255C05
1.021,1.292 1.146,1.719 1.146,1.719 1.281,1.719 false 0.49,1.219 0.417,1.656 0.417,1.656 0.271,1.656 false 0.719,0.927 0.594,0.563 0.594,0.563 0.354,0.563 false 1.01,0.896 1.208,0.531 1.208,0.531 1.344,0.531 false 1.813,1.427 1.969,1.625 0.156,0.198 10 false 1 1.813,0.771 1.969,0.969 0.156,0.198 10 false 3 3.135,1.417 3.292,1.615 0.156,0.198 10 false 2 3.135,0.781 3.292,0.979 0.156,0.198 10 false 5 0.156,1.583 0.313,1.781 0.156,0.198 10 false 3 1.333,1.635 1.49,1.833 0.156,0.198 10 false 2 1.375,0.438 1.531,0.635 0.156,0.198 10 false 1 0.25,0.49 0.406,0.688 0.156,0.198 10 false 5 0.083,0.073 0.406,0.292 0.323,0.219 10 false *a
*a Component without harness connected
(PTC Heater Relay (PTC_No. 1, PTC_No. 2, PTC_No. 3))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the PTC heater relay (PTC_No. 1, PTC_No. 2, PTC_No. 3).


Hide 2.INSPECT CONDENSER FAN RELAY

a.
E374255C05
1.021,1.292 1.146,1.719 1.146,1.719 1.281,1.719 false 0.49,1.219 0.417,1.656 0.417,1.656 0.271,1.656 false 0.719,0.927 0.594,0.563 0.594,0.563 0.354,0.563 false 1.01,0.896 1.208,0.531 1.208,0.531 1.344,0.531 false 1.813,1.427 1.969,1.625 0.156,0.198 10 false 1 1.813,0.771 1.969,0.969 0.156,0.198 10 false 3 3.135,1.417 3.292,1.615 0.156,0.198 10 false 2 3.135,0.781 3.292,0.979 0.156,0.198 10 false 5 0.156,1.583 0.313,1.781 0.156,0.198 10 false 3 1.333,1.635 1.49,1.833 0.156,0.198 10 false 2 1.375,0.438 1.531,0.635 0.156,0.198 10 false 1 0.25,0.49 0.406,0.688 0.156,0.198 10 false 5 0.083,0.073 0.406,0.292 0.323,0.219 10 false *a
*a Component without harness connected
(Condenser Fan Relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the condenser fan relay.


Hide 87120F 3.INSPECT VISCOUS HEATER RELAY (w/ Viscous Heater)

a.
E374255C05
1.021,1.292 1.146,1.719 1.146,1.719 1.281,1.719 false 0.49,1.219 0.417,1.656 0.417,1.656 0.271,1.656 false 0.719,0.927 0.594,0.563 0.594,0.563 0.354,0.563 false 1.01,0.896 1.208,0.531 1.208,0.531 1.344,0.531 false 1.813,1.427 1.969,1.625 0.156,0.198 10 false 1 1.813,0.771 1.969,0.969 0.156,0.198 10 false 3 3.135,1.417 3.292,1.615 0.156,0.198 10 false 2 3.135,0.781 3.292,0.979 0.156,0.198 10 false 5 0.156,1.583 0.313,1.781 0.156,0.198 10 false 3 1.333,1.635 1.49,1.833 0.156,0.198 10 false 2 1.375,0.438 1.531,0.635 0.156,0.198 10 false 1 0.25,0.49 0.406,0.688 0.156,0.198 10 false 5 0.083,0.073 0.406,0.292 0.323,0.219 10 false *a
*a Component without harness connected
(Viscous Heater Relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the viscous heater relay.