1.INSPECT PTC HEATER RELAY(PTC_NO. 1, PTC_NO. 2, PTC_NO. 3)
| *a | Component without harness connected (PTC Heater Relay (PTC_No. 1, PTC_No. 2, PTC_No. 3)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the PTC heater relay (PTC_No. 1, PTC_No. 2, PTC_No. 3).
2.INSPECT CONDENSER FAN RELAY
| *a | Component without harness connected (Condenser Fan Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the condenser fan relay.
87120F 3.INSPECT VISCOUS HEATER RELAY (w/ Viscous Heater)
| *a | Component without harness connected (Viscous Heater Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the viscous heater relay.