CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
Disconnect the I33 and I31*1, *2 air conditioning amplifier assembly connectors.
Measure the resistance and voltage according to the value(s) in the table below.
| Terminal No. (Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
|
*1: w/ Rear Cooler *2: w/ Rear Air Conditioning System |
|||
| I33-5 (B) - Body ground | Power source | Always | 11 to 14 V |
| I33-6 (IG+) - Body ground | Power source | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | ||
| I33-17 (GND) - Body ground | Ground | Always | Below 1 Ω |
| I31-1 (+B2) - Body ground*1, *2 | Power source | Always | 11 to 14 V |
| I31-4 (GND2) - Body ground*1, *2 | Ground | Always | Below 1 Ω |
Reconnect the I33 and I31*1, *2 air conditioning amplifier assembly connectors.
Measure the voltage and resistance and check for pulse according to the value(s) in the table below.
| Terminal No. (Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
|
*1: w/ Rear Cooler *2: w/ Rear Air Conditioning System *3: w/ Ion Generator *4: w/ PTC Heater *5: w/ Condenser Fan *6: w/ Cooling Box *7: Value when sensor power source voltage is 5 V *8: w/ Viscous Heater *9: w/ Idle Up Switch |
|||
| I33-1 (CANL) | CAN communication line | - | - |
| I33-2 (CANH) | CAN communication line | - | - |
| I33-3 (ACT) - Body ground | Magnet clutch on permit input signal |
·
Engine running
·
Blower switch: On (LO level)
·
A/C switch: Off or on (magnet clutch off) |
Below 1 V |
|
·
Engine running
·
Blower switch: On (LO level)
·
A/C switch: On (magnet clutch on) |
4.5 to 5.5 V | ||
| I33-4 (NAIN) - Body ground*3 | Ion generator sub-assembly operation condition signal |
·
Ignition switch ON
·
Blower switch: On |
Below 2.2 V |
|
·
Ignition switch ON
·
Blower switch: Off |
4.75 to 5.25 V | ||
| I33-7 (LIN1) - Body ground | LIN communication signal | Ignition switch ON | Pulse generation (See waveform 1) |
| I33-12 (SW 1) - Body ground*8, *9 |
·
Heater switch assembly operation signal*8
·
Idle up switch operation signal*9 |
·
Engine running
·
A/C switch: On
·
Blower switch: On (LO level)
·
Heater switch assembly: Off → on*8
·
Idle up switch: Off → on*9 |
11 to 14 V → Below 1 V |
| I33-19 (AC1) - Body ground | Idle-up request signal |
·
Engine running
·
Blower switch: On (LO level)
·
A/C switch: Off |
11 to 14 V |
|
·
Engine running
·
Blower switch: On (LO level)
·
A/C switch: On |
Below 1 V | ||
| I33-21 (BLW) - Body ground | Blower motor speed control signal |
·
Ignition switch ON
·
Blower switch: LO |
Pulse generation (See waveform 2) |
| I33-23 (PTC1) - Body ground*4 | Quick heater assembly operation signal |
·
Engine running
·
ECO mode switch: Off
·
Temperature settings: MAX HOT
·
Ambient temperature: 25°C (77°F) or lower
·
Engine coolant temperature: 75°C (167°F) or lower
·
Light control switch: Off
·
Blower switch: Off → on (after 10 seconds) |
11 to 14 V → Below 1 V |
| I33-24 (NANO) - Body ground*3 | Ion generator sub-assembly operation signal |
·
Ignition switch ON
·
Blower switch: On |
Below 1 V |
|
·
Ignition switch ON
·
Blower switch: Off |
4.75 to 5.25 V | ||
| I32-1 (TAM) - Body ground | Thermistor assembly (ambient temperature sensor) signal |
·
Ignition switch ON
·
Ambient temperature: 25°C (77°F) |
1.05 to 1.45 V |
|
·
Ignition switch ON
·
Ambient temperature: 40°C (104°F) |
0.64 to 0.87 V | ||
| I32-3 (SG-1) - Body ground | Ground for sensor | Always | Below 1 Ω |
| I32-4 (SG-5) - Body ground*1 | Ground for sensor | Always | Below 1 Ω |
| I32-5 (TR) - Body ground | Cooler thermistor (room temperature sensor) signal |
·
Ignition switch ON
·
Cabin temperature: 25°C (77°F) |
1.05 to 1.45 V |
|
·
Ignition switch ON
·
Cabin temperature: 40°C (104°F) |
0.64 to 0.87 V | ||
| I32-6 (PRE) - Body ground | Air conditioning pressure sensor signal |
·
Engine running
·
Air conditioning system operating
·
Refrigerant pressure: Normal pressure (less than 3025 kPaG (30.8 kgf/cm2, 439 psi) and more than 176 kPaG (1.8 kgf/cm2, 26 psi)) |
0.62 to 4.73 V*7 |
| I32-7 (BSET) - Body ground*1 | Volume switch of cooler control switch assembly signal |
·
Ignition switch ON
·
Blower switch: Off → HI |
Below 1 → 5.15 V |
| I32-11 (S5-3) - Body ground | Power supply for air conditioning pressure sensor | Ignition switch ON | 4.75 to 5.25 V |
| Ignition switch off | Below 1 V | ||
| I32-12 (LOCK) - Body ground | Compressor lock sensor signal |
·
Engine running
·
A/C switch: On (magnet clutch on)
·
Blower switch: LO |
Pulse generation (See waveform 3) |
| I32-13 (S5-2) - Body ground*1 | Power supply for cooler control switch assembly |
·
Ignition switch ON
·
Blower switch: Off → HI |
Below 1 V → 4.85 to 5.15 V |
| I32-14 (SG-2) - Body ground | Ground for sensor | Always | Below 1 Ω |
| I32-15 (SG-4) - Body ground | Ground for sensor | Always | Below 1 Ω |
| I32-16 (PTC2) - Body ground*4 | Quick heater assembly operation signal |
·
Engine running
·
ECO mode switch: Off
·
Temperature settings: MAX HOT
·
Ambient temperature: 16°C (61°F) or lower
·
Engine coolant temperature: 70°C (158°F) or lower
·
Light control switch: Off
·
Blower switch: Off → on (after 20 seconds) |
11 to 14 V → Below 1 V |
| I32-17 (PTC3) - Body ground*4 | Quick heater assembly operation signal |
·
Engine running
·
ECO mode switch: Off
·
Temperature settings: MAX HOT
·
Ambient temperature: -7°C (19°F) or lower
·
Engine coolant temperature: 65°C (149°F) or lower
·
Light control switch: Off
·
Blower switch: Off → on (after 30 seconds) |
11 to 14 V → Below 1 V |
| I32-19 (MGC) - Body ground | Magnet clutch operation signal |
·
Engine running
·
Blower switch: LO
·
A/C switch: On (magnet clutch on) |
Below 1 V |
|
·
Engine running
·
Blower switch: LO
·
A/C switch: Off or on (magnet clutch off) |
11 to 14 V | ||
| I32-20 (CFAN) - Body ground*5 | Condenser fan operation signal | Ignition switch ON | 11 to 14 V |
| I32-21 (MGCA) - Body ground*8 | Viscous heater with magnetic clutch assembly operation signal |
·
Engine running
·
Blower switch: On (LO level)
·
Heater switch assembly: Off or on (magnet clutch off) |
11 to 14 V |
|
·
Engine running
·
Blower switch: On (LO level)
·
Heater switch assembly: On (magnet clutch on) |
Below 1 V | ||
| I31-2 (RBBU) - Body ground*2 | Power supply for BUS IC (for Rear) | Always | 11 to 14 V |
| I31-3 (RBUG) - Body ground*2 | Ground for BUS IC (for Rear) | Always | Below 1 Ω |
| I31-6 (RMGV) - Body ground*1, *2 | Rear cooling unit expansion valve signal |
·
Ignition switch ON
·
Blower switch: LO
·
A/C switch: On |
11 to 14 V |
| I31-7 (RBUS) - Body ground*2 | BUS IC control signal (for Rear) | Ignition switch ON | Pulse generation (see waveform 4) |
| I31-10 (SBLW) - Body ground*1, *2 | Blower motor speed control signal |
·
Ignition switch ON
·
Blower switch: LO |
Pulse generation (See waveform 2) |
| I31-20 (RLIN) - Body ground*2 | LIN communication signal | Ignition switch ON | Pulse generation (See waveform 1) |
| I30-8 (RRTR) - Body ground*1, *2 | Room temperature sensor signal (for Rear RH) |
·
Ignition switch ON
·
Vehicle interior temperature: 25°C (77°F) |
1.9 to 2.1 V |
|
·
Ignition switch ON
·
Vehicle interior temperature: 50°C (122°F) |
1.0 to 1.2 V | ||
| I30-10 (RLTR) - Body ground*1, *2 | Room temperature sensor signal (for Rear LH) |
·
Ignition switch ON
·
Vehicle interior temperature: 25°C (77°F) |
1.9 to 2.1 V |
|
·
Ignition switch ON
·
Vehicle interior temperature: 50°C (122°F) |
1.0 to 1.2 V | ||
| I30-11 (TEC) - Body ground*2 | No. 2 cooler thermistor signal |
·
Ignition switch ON
·
Evaporator temperature: 0°C (32°F) |
1.7 to 2.1 V |
|
·
Ignition switch ON
·
Evaporator temperature: 15°C (59°F) |
0.9 to 1.3 V | ||
| I30-14 (SG-8) - Body ground*1, *2 | Ground for sensor | Always | Below 1 Ω |
| I30-15 (SG-9) - Body ground*2 | Ground for sensor | Always | Below 1 Ω |
| I30-17 (SWCB) - Body ground*6 | Cool box drive permit signal |
·
Ignition switch ON
·
Cool box switch: Off → on |
Below 1 V → 4.5 to 5.5 V |
| I30-19 (COOL) - Body ground*6 | Cool box drive request signal |
·
Ignition switch ON
·
Cool box switch: Off → on |
11 to 14 V → Below 1 V |
| z16-2 (BUSG) - Body ground | Ground for BUS IC (for Front) | Always | Below 1 Ω |
| z16-3 (BUS) - Body | BUS IC control signal (for Front) | Ignition switch ON | Pulse generation (see waveform 4) |
| z16-4 (BBUS) - Body ground | Power supply for BUS IC (for Front) | Always | 11 to 14 V |
| z16-5 (SG-3) - Body ground | Ground for sensor | Always | Below 1 Ω |
| z16-6 (TE) - Body ground | No. 1 cooler thermistor signal |
·
Ignition switch ON
·
Evaporator temperature: 0°C (32°F) |
1.7 to 2.1 V |
|
·
Ignition switch ON
·
Evaporator temperature: 15°C (59°F) |
0.9 to 1.3 V | ||
Using an oscilloscope, check waveform 1.
| Item | Content |
|---|---|
|
*: w/ Rear Air Conditioning System |
|
| Terminal No. |
·
I33-7 (LIN1) - Body ground
·
I31-20 (RLIN) - Body ground* |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Ignition switch ON |
Using an oscilloscope, check waveform 2.
| Item | Content |
|---|---|
|
*1: w/ Rear Cooler *2: w/ Rear Air Conditioning System |
|
| Terminal No. |
·
I33-21 (BLW) - Body ground
·
I31-10 (SBLW) - Body ground*1, *2 |
| Tool Setting | 2 V/DIV., 1 ms./DIV. |
| Condition |
·
Ignition switch ON
·
Blower switch: LO |
The waveform varies with the blower speed.
Using an oscilloscope, check waveform 3.
| Item | Content |
|---|---|
| Terminal No. | I32-12 (LOCK) - Body ground |
| Tool Setting | 200 mV/DIV., 10 ms./DIV. |
| Condition |
·
Engine running
·
A/C switch: On (magnet clutch on)
·
Blower switch: LO |
When the engine speed is increased, the duty ratio changes accordingly.
Using an oscilloscope, check waveform 4.
| Item | Content |
|---|---|
|
*: w/ Rear Air Conditioning System |
|
| Terminal No. |
·
z16-3 (BUS) - Body ground
·
I31-7 (RBUS) - Body ground* |
| Tool Setting | 2 V/DIV., 2 ms./DIV. |
| Condition | Ignition switch ON |
CHECK AIR CONDITIONING CONTROL ASSEMBLY
Disconnect the I78 air conditioning control assembly connector.
Measure the resistance and voltage according to the value(s) in the table below.
| Terminal No. (Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| I78-4 (E) - Body ground | Ground | Always | Below 1 Ω |
| I78-7 (ACC) - Body ground | Power source | Ignition switch off | Below 1 V |
| Ignition switch ACC | 11 to 14 V | ||
| I78-8 (IG+) - Body ground | Power source | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | ||
| I78-16 (+B) - Body ground | Power source | Always | 11 to 14 V |
Reconnect the I78 air conditioning control assembly connector.
Check for pulse according to the value(s) in the table below.
| Terminal No. (Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| I78-3 (LIN1) - Body ground | LIN communication signal | Ignition switch ON | Pulse generation (see waveform 1) |
Using an oscilloscope, check waveform 1.
| Item | Content |
|---|---|
| Terminal No. | I78-3 (LIN1) - Body ground |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Ignition switch ON |
CHECK COOLER CONTROL SWITCH ASSEMBLY (w/ Rear Cooler)
Disconnect the Q34 cooler control switch assembly connector.
Measure the resistance and voltage according to the value(s) in the table below.
| Terminal No. (Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| Q34-4 (SG) - Body ground | Ground | Always | Below 1 Ω |
| Q34-2 (S5) - Body ground | Power source |
·
Ignition switch off
·
Blower switch: Off → HI |
Below 1 V → 4.85 to 5.15 V |
Reconnect the Q34 cooler control switch assembly connector.
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| Q34-3 (BSET) - Body ground | Volume switch of No. 2 air conditioning control assembly signal |
·
Ignition switch off
·
Blower switch: Off → HI |
Below 1 → 5.15 V |
CHECK COOLER CONTROL SWITCH ASSEMBLY (w/ Rear Air Conditioning System)
Disconnect the Q52 cooler control switch assembly connector.
Measure the resistance and voltage according to the value(s) in the table below.
| Terminal No. (Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| Q52-6 (E) - Body ground | Ground | Always | Below 1 Ω |
| Q52-10 (IG+) - Body ground | Power source | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V |
Reconnect the Q52 cooler control switch assembly connector.
Check for pulse according to the value(s) in the table below.
| Terminal No. (Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| Q52-5 (RLIN) - Body ground | LIN communication signal | Ignition switch ON | Pulse generation (see waveform 1) |
Using an oscilloscope, check waveform 1.
| Item | Content |
|---|---|
| Terminal No. | Q52-5 (RLIN) - Body ground |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Ignition switch ON |