Home › Power Source / Network › F33A-FTV (BATTERY / CHARGING) › CHARGING SYSTEM › from 2021.07
RM38G0E _57 Power Source / Network _106328 F33A-FTV BATTERY / CHARGING _0489033 CHARGING SYSTEM U

F33A-FTV BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECM  


CHECK ECM


B460712E31
2.104,0.781 2.552,1.021 0.448,0.24 3.813,0.792 4.26,1.031 0.448,0.24 5.344,0.781 5.802,1.021 0.458,0.24 2.167,0.823 2.781,1.021 0.615,0.198 10 false C138 3.875,0.844 4.49,1.042 0.615,0.198 10 false C139 5.448,0.823 6.063,1.021 0.615,0.198 10 false B70

HINT:

The standard normal voltage and resistance between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage and resistance for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


Terminal No. (Symbol) Terminal Description Condition Specified Condition
B70-1 (BATT) - B70-10 (E1) Battery (for measuring battery voltage and for ECM memory) Always 11 to 14 V
B70-10 (E1) - Body ground Ground Always Below 1 Ω
B70-13 (LIN) - Body ground LIN communication line Ignition switch off
(while LIN communication stopped)
10 kΩ or higher