Home › Power Source / Network › F33A-FTV (BATTERY / CHARGING) › CHARGING SYSTEM › from 2021.07
RM38G0E _57 Power Source / Network _106328 F33A-FTV BATTERY / CHARGING _0489033 CHARGING SYSTEM U

F33A-FTV BATTERY / CHARGING  CHARGING SYSTEM  DATA LIST / ACTIVE TEST  


DATA LIST


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under Normal Condition are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Warm up the engine.


b.

Turn the A/C switch off.


c.

Turn the ignition switch off.


d.

Connect the GTS to the DLC3.


e.

Turn the ignition switch to ON.


f.

Turn the GTS on.


g.

Enter the following menus: Powertrain / Engine / Data List.


h.

According to the display on the GTS, read the Data List.

HINT:

Normal Condition: If no conditions are specifically stated for "idling", the shift lever should be in P, the A/C switch should be off and all accessory switches should be off.


Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Voltage Battery voltage Min.: 0.0 V
Max.: 65.5 V
11 to 14 V: Idling If 11 V or less, characteristics of some electrical components may change.
Battery Sensor Voltage Battery sensor voltage Min.: 0 V
Max.: 79.998 V
- -
Total Distance Indicated after Long Term Leaving with IG OFF (1st) Cumulative distance before 1st long term ignition switch off period of time (1440 hours (60 days)) Min.: 0 km
Max: 131070 km
- -
Total Distance Indicated after Long Term Leaving with IG OFF (2nd) Cumulative distance before 2st long term ignition switch off period of time (1440 hours (60 days)) Min.: 0 km
Max: 131070 km
- -
Total Distance Indicated after Long Term Leaving with IG OFF (3rd) Cumulative distance before 3st long term ignition switch off period of time (1440 hours (60 days)) Min.: 0 km
Max: 131070 km
- -
Time of Long Term Leaving with IG OFF (1st) Number of days of 1st long term ignition switch off period of time (1440 hours (60 days)) Min.: 0 day
Max.: 255 day
- -
Time of Long Term Leaving with IG OFF (2nd) Number of days of 2st long term ignition switch off period of time (1440 hours (60 days)) Min.: 0 day
Max.: 255 day
- -
Time of Long Term Leaving with IG OFF (3rd) Number of days of 3st long term ignition switch off period of time (1440 hours (60 days)) Min.: 0 day
Max.: 255 day
- -
IG ON Time Up to 1 trip before Time ignition switch was ON 1 trip before Min.: 0 min
Max.: 510 min
- -
IG ON Time Up to 2 trip before Time ignition switch was ON 2 trip before Min.: 0 min
Max.: 510 min
- -
IG ON Time Up to 3 trip before Time ignition switch was ON 3 trip before Min.: 0 min
Max.: 510 min
- -
IG ON Time Up to 4 trip before Time ignition switch was ON 4 trip before Min.: 0 min
Max.: 510 min
- -
IG ON Time Up to 5 trip before Time ignition switch was ON 5 trip before Min.: 0 min
Max.: 510 min
- -
Auxiliary Battery Average Current during IG OFF 1 Trip before Average battery current when ignition switch off 1 trip before Min.: -32.768 A
Max: 32.767 A
- -
Auxiliary Battery Average Current during IG OFF 2 Trip before Average battery current when ignition switch off 2 trip before Min.: -32.768 A
Max: 32.767 A
- -
Auxiliary Battery Average Current during IG OFF 3 Trip before Average battery current when ignition switch off 3 trip before Min.: -32.768 A
Max: 32.767 A
- -
Auxiliary Battery Average Current during IG OFF 4 Trip before Average battery current when ignition switch off 4 trip before Min.: -32.768 A
Max: 32.767 A
- -
Auxiliary Battery Average Current during IG OFF 5 Trip before Average battery current when ignition switch off 5 trip before Min.: -32.768 A
Max: 32.767 A
- -
Engine Run Time before 1 trip Total time ignition switch was turned on during previous trip (1) Min.: 0 min
Max.: 510 min
- -
Engine Run Time before 2 trip Total time ignition switch was turned on during previous trip (2) Min.: 0 min
Max.: 510 min
- -
Engine Run Time before 3 trip Total time ignition switch was turned on during previous trip (3) Min.: 0 min
Max.: 510 min
- -
Engine Run Time before 4 trip Total time ignition switch was turned on during previous trip (4) Min.: 0 min
Max.: 510 min
- -
Engine Run Time before 5 trip Total time ignition switch was turned on during previous trip (5) Min.: 0 min
Max.: 510 min
- -
Total Distance Up to 1 Trip before Cumulative distance traveled 1 trip before Min.: 0 km
Max: 131070 km
- -
Total Distance Up to 2 Trip before Cumulative distance traveled 2 trip before Min.: 0 km
Max: 131070 km
- -
Total Distance Up to 3 Trip before Cumulative distance traveled 3 trip before Min.: 0 km
Max: 131070 km
- -
Total Distance Up to 4 Trip before Cumulative distance traveled 4 trip before Min.: 0 km
Max: 131070 km
- -
Total Distance Up to 5 Trip before Cumulative distance traveled 5 trip before Min.: 0 km
Max: 131070 km
- -
Battery Current Battery current Min.: -125.0 A
Max.: 124.9 A
Changes according to alternator output (While driving after engine warmed up) If the result is not as specified, a malfunction of the LIN communication line is suspected.
Battery Temperature Battery temperature Min.: -40.0°C (-40°F)
Max.: 6513.5 °C (11756 °F)
Changes according to actual temperature (While driving after engine warmed up) If the result is not as specified, a malfunction of the LIN communication line is suspected.
Alternator Output Duty Ratio Generator output duty ratio Min.: 0.0%
Max.: 399.9%
- -
Status of Alternator Temperature High Alternator high temperature status ON or OFF - -
Alternator Voltage - Non Active Test Request voltage when regulator not under forced activation Min.: 0.0 V
Max.: 79.998 V
Battery electrolyte temperature varies (12.7 to 15.3 V) while driving: After engine start -
Voltage of Alternator Alternator voltage Min.: 0.0 V
Max.: 79.99 V
- -
Auxiliary Battery Charging Integrated Current Cumulative battery charging integrated current value since vehicle was built Min.: 0.0 Ah
Max.: 429496729.5 Ah
- -
Auxiliary Battery Discharging Integrated Current Cumulative battery discharging integrated current value since vehicle was built Min.: 0.0 Ah
Max.: 429496729.5 Ah
- -
Auxiliary Battery Integrated Thermal Load Cumulative battery thermal load since vehicle was built Min.: 0.0
Max.: 4294967295
- -
Auxiliary Battery Capacity after IG ON Battery level just after ignition switch turned to ON Min.: -128 Ah
Max.: 127 Ah
- -
Auxiliary Battery Capacity after IG OFF Battery level just after ignition switch turned off Min.: -128 Ah
Max.: 127 Ah
- -
Integrated Engine Run Time Cumulative time ignition switch has been ON since vehicle was built Min.: 0 hour
Max.: 65535 hour
- -
Number of Long Term Leaving with IG OFF Number of times ignition switch not changed from off for long period of time (1440 hours (60 days)) Min.: 0, Max.: 255 - -
Previous Trip Alternator Max Output Time Accumulated time of maximum power generation by alternator during previous trip Min.: 0 sec
Max.: 65535 sec
- -
Initial Engine Battery Minimum Voltage Minimum battery voltage at engine start Min.: 0 V
Max.: 25.5 V
- -
Previous Trip Charge Control Time Previous trip charge control time Min.: 0 sec
Max.: 65535 sec
- -
Previous Trip Average Battery Temperature Previous trip Average battery temperature Min.: -40°C
Max.: 215°C
- -
Battery Charging Rate Accuracy Battery charging rate accuracy Low/Middle/High/Disable - -
Auxiliary Battery Charging Rate Feedback Value Collection value for SOC based on battery full charging Min.: 0.0%
Max.: 6553.5%
- -
Auxiliary Battery Charging Rate Controlling Value SOC value recognized by charging control system Min.: 0.0%
Max.: 6553.5%
- Changes in accordance with the Data List "Auxiliary Battery Charging Rate Feedback Value".
Battery Status of Full Charge Battery status of full charge Min.: 0 Ah
Max.: 127.5 Ah
- -
IG OFF Time before 1 trip Number of days ignition switch was off 1 trip before Min.: 0 day
Max.: 255 day
- -
IG OFF Time before 2 trip Number of days ignition switch was off 2 trip before Min.: 0 day
Max.: 255 day
- -
IG OFF Time before 3 trip Number of days ignition switch was off 3 trip before Min.: 0 day
Max.: 255 day
- -
IG OFF Time before 4 trip Number of days ignition switch was off 4 trip before Min.: 0 day
Max.: 255 day
- -
IG OFF Time before 5 trip Number of days ignition switch was off 5 trip before Min.: 0 day
Max.: 255 day
- -


ACTIVE TEST


HINT:

Using the GTS, perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine / Active Test.


e.

According to the display on the GTS, perform the Active Test.

Powertrain > Engine > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Control the Voltage of Alternator Requested output voltage of generator regulator during forced activation 12.5 to 14.7 V Perform this test when vehicle is stopped.