1.INSPECT VACUUM PUMP HOUSING
|
Contact Surface of Vacuum Pump Vane Cap |
Check that there is no foreign matter in the vacuum pump housing.
If there is damage, replace the vacuum pump assembly.
Visually inspect the contact surface of the vacuum pump vane cap of the vacuum pump housing.
If there is damage, replace the vacuum pump assembly.
2.INSPECT VACUUM PUMP VANE
Check that the vacuum pump vane or vacuum pump vane caps are not damaged or excessively worn out.
If the vacuum pump vane or vacuum pump vane caps are damaged or excessively worn out, replace the damaged parts with new ones.
| *a | 10 mm (0.394 in.) |
Using a micrometer, measure length A of the vacuum pump with the vacuum pump vane caps removed.
23.8 mm (0.937 in.)
Measure the 10 mm (0.394 in.) in from each end of the vacuum pump vane.
If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones.
| *1 | Vacuum Pump Vane |
| *2 | Vacuum Pump Vane Cap |
| *a | 5 mm (0.197 in.) |
Using a vernier caliper, measure length B of the vacuum pump vane with the vacuum pump vane caps installed.
85.0 mm (3.35 in.)
Measure the length 5 mm (0.197 in.) in from each end of the vacuum pump vane caps.
If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones.
3.INSPECT VACUUM PUMP HOUSING
Check that the rotor part, coupling, vacuum pump housing or vacuum end cover is not damaged or excessively worn out.
If the rotor part, coupling, vacuum pump housing or vacuum end cover is damaged or excessively worn out, replace the vacuum pump assembly.