Home › General › SPECIFICATIONS › F33A-FTV INTAKE / EXHAUST › from 2021.07
RM38G0E _V1 General _100727 SPECIFICATIONS _0491967 F33A-FTV INTAKE / EXHAUST F

SPECIFICATIONS  F33A-FTV INTAKE / EXHAUST  SERVICE DATA  


VACUUM SWITCHING VALVE
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 37 to 44 Ω
1 - Body ground
2 - Body ground
20°C (68°F) 1 MΩ or higher

EXHAUST MANIFOLD W/ TURBOCHARGER
Axial play of turbine shaft Standard 0.11 mm (0.00433 in.)
Turbocharger variable nozzle motor C159-1 (M-) - C159-2 (M+) Condition 20°C (68°F) 1 to 100 Ω
No. 2 turbocharger variable nozzle motor C163-1 (M-) - C163-2 (M+) Condition 20°C (68°F) 1 to 100 Ω
Turbocharger variable nozzle motor C159-1 (M-) - Body ground
C159-2 (M+) - Body ground
Condition always 1 MΩ or higher
No. 2 turbocharger variable nozzle motor C163-1 (M-) - Body ground
C163-2 (M+) - Body ground
Condition always 1 MΩ or higher
Air by-pass valve assembly C160-1 (ABV) - C160-2 (+B) Condition 20°C (68°F) 8.6 to 9.6 Ω

EXHAUST PIPE
Compression spring Minimum free length Center exhaust pipe side 43 mm (1.69 in.)
Tail exhaust pipe side 42 mm (1.65 in.)

RADIATOR
Item Condition Specified Condition
Reserve tank cap (for Intercooler) Standard pressure
(for brand-new cap)
93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi)
Minimum pressure
(for used cap)
79 kPa (0.8 kgf/cm2, 11.4 psi)