896B1A 1.INSPECT DCU MAIN RELAY (DCU)
Measure the resistance.
| Tester Connection | Test Condition | Resistance |
|---|---|---|
| 3 - 5 | - | 10 kΩ or higher |
| Apply 12V across 1 and 2 | Below 1 Ω |
If the result is not as specified, replace it.
89870E 2.INSPECT ELECTRONIC DRIVER UNIT RELAY (EDU)
Measure the resistance.
| Tester Connection | Test Condition | Resistance |
|---|---|---|
| 3 - 5 | - | 10 kΩ or higher |
| Apply 12V across 1 and 2 | Below 1 Ω |
If the result is not as specified, replace it.
89561F 3.INSPECT NO. 1 ELECTRONIC FUEL INJECTION MAIN RELAY (EFI MAIN NO. 1)
Measure the resistance.
| Tester Connection | Test Condition | Resistance |
|---|---|---|
| 3 - 5 | - | 10 kΩ or higher |
| Apply 12V across 1 and 2 | Below 1 Ω |
If the result is not as specified, replace it.
89561G 4.INSPECT NO. 2 ELECTRONIC FUEL INJECTION MAIN RELAY (EFI MAIN NO. 2)
Measure the resistance.
| Tester Connection | Test Condition | Resistance |
|---|---|---|
| 3 - 5 | - | 10 kΩ or higher |
| Apply 12V across 1 and 2 | Below 1 Ω |
If the result is not as specified, replace it.
89561H 5.INSPECT NO. 3 ELECTRONIC FUEL INJECTION MAIN RELAY (EFI MAIN NO. 3)
Measure the resistance.
| Tester Connection | Test Condition | Resistance |
|---|---|---|
| 3 - 5 | - | 10 kΩ or higher |
| Apply 12V across 1 and 2 | Below 1 Ω |
If the result is not as specified, replace it.
6.INSPECT FUEL FILTER RELAY (FUEL FIL)
Measure the resistance.
| Tester Connection | Test Condition | Resistance |
|---|---|---|
| 3 - 5 | - | 10 kΩ or higher |
| Apply 12V across 1 and 2 | Below 1 Ω |
If the result is not as specified, replace it.
28371L 7.INSPECT IGP RELAY (IGP NO.1)
Measure the resistance.
| Tester Connection | Test Condition | Resistance |
|---|---|---|
| 3 - 5 | - | 10 kΩ or higher |
| Apply 12V across 1 and 2 | Below 1 Ω |
If the result is not as specified, replace it.
28371M 8.INSPECT NO.2 IGP RELAY (IGP NO.2)
Measure the resistance.
| Tester Connection | Test Condition | Resistance |
|---|---|---|
| 3 - 5 | - | 10 kΩ or higher |
| Apply 12V across 1 and 2 | Below 1 Ω |
If the result is not as specified, replace it.
9.INSPECT IGR RELAY (IGR NO.3)
Measure the resistance.
| Tester Connection | Test Condition | Resistance |
|---|---|---|
| 3 - 5 | - | 10 kΩ or higher |
| Apply 12V across 1 and 2 | Below 1 Ω |
If the result is not as specified, replace it.
89463B 10.INSPECT NITROGEN OXIDES RELAY (NOx)
Measure the resistance.
| Tester Connection | Test Condition | Resistance |
|---|---|---|
| 3 - 5 | - | 10 kΩ or higher |
| Apply 12V across 1 and 2 | Below 1 Ω |
If the result is not as specified, replace it.