89424B 1.INSPECT INTAKE AIR TEMPERATURE SWITCH (for Inlet Side)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(C114)Location & Routingewd_type=routing;type=c;code=C114 |
||
| C114-1 (T3) - C114-2 (ET3) | 25°C (77°F) | 15.94 to 18.53 kΩ |
If the result is not as specified, replace the intake air temperature sensor.
89424B 2.INSPECT INTAKE AIR TEMPERATURE SWITCH (for Outlet Side)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(C171)Location & Routingewd_type=routing;type=c;code=C171 |
||
| C171-1 (THA) - C171-2 (E2) | 25°C (77°F) | 15.94 to 18.53 kΩ |
If the result is not as specified, replace the intake air temperature sensor.