Do not put your hands into the water that has been heated for the inspection.
Touching the heated water could result in burns.
89454 1.INSPECT FUEL TEMPERATURE SENSOR
Do not put your hands into the water that has been heated for the inspection.
Touching the heated water could result in burns.
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected (Fuel Temperature Sensor) |
*b | Resistance (Ω) |
| *c | Temperature (°C) | - | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(V18)Location & Routingewd_type=routing;type=c;code=V18 Click Connector(V18)Body>Differential Wire / Frame Wire>Fuel Temperature Sensorewd_type=component;type=c;code=V18;pinno=1,2 |
||
| V18-1(E2) - V18-2(THF) | 20°C (68°F) | 2.31 to 2.58 kΩ |
| V18-1(E2) - V18-2(THF) | 80°C (176°F) | 0.310 to 0.326 kΩ |
If checking the fuel temperature sensor in water, be careful not to allow water to contact the terminals. After checking, wipe the water off the fuel temperature sensor.
If the result is not as specified, replace the fuel temperature sensor.