23670 1.INSPECT INJECTOR ASSEMBLY
Inspect the injector assembly.
| *a | Component without harness connected (Injector Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(C117,C118,C119,C120,C121,C122)Location & Routingewd_type=routing;type=c,c,c,c,c,c;code=C117,C118,C119,C120,C121,C122 |
||
| C117-1(EIJ1) - C117-4(PIJ1) | 25°C (77°F) | 16.4 kΩ or less |
| C118-1(EIJ2) - C118-4(PIJ2) | 25°C (77°F) | 16.4 kΩ or less |
| C119-1(EIJ3) - C119-4(PIJ3) | 25°C (77°F) | 16.4 kΩ or less |
| C120-1(EIJ4) - C120-4(PIJ4) | 25°C (77°F) | 16.4 kΩ or less |
| C121-1(EIJ5) - C121-4(PIJ5) | 25°C (77°F) | 16.4 kΩ or less |
| C122-1(EIJ6) - C122-4(PIJ6) | 25°C (77°F) | 16.4 kΩ or less |
| C117-2(VIJ1) - C117-4(PIJ1) | 25°C (77°F) | 3.5 kΩ or less |
| C118-2(VIJ2) - C118-4(PIJ2) | 25°C (77°F) | 3.5 kΩ or less |
| C119-2(VIJ3) - C119-4(PIJ3) | 25°C (77°F) | 3.5 kΩ or less |
| C120-2(VIJ4) - C120-4(PIJ4) | 25°C (77°F) | 3.5 kΩ or less |
| C121-2(VIJ5) - C121-4(PIJ5) | 25°C (77°F) | 3.5 kΩ or less |
| C122-2(VIJ6) - C122-4(PIJ6) | 25°C (77°F) | 3.5 kΩ or less |
| C117-3(#1) - C117-6(#10) | 20°C (68°F) | 0.52 to 0.66 Ω |
| C118-3(#2) - C118-6(#20) | 20°C (68°F) | 0.52 to 0.66 Ω |
| C119-3(#3) - C119-6(#30) | 20°C (68°F) | 0.52 to 0.66 Ω |
| C120-3(#4) - C120-6(#40) | 20°C (68°F) | 0.52 to 0.66 Ω |
| C121-3(#5) - C121-6(#50) | 20°C (68°F) | 0.52 to 0.66 Ω |
| C122-3(#6) - C122-6(#60) | 20°C (68°F) | 0.52 to 0.66 Ω |
If the result is not as specified, replace the injector assembly.