| Item | Tester Connection | Switch Condition | Specified Condition |
|---|---|---|---|
| TOWING CONVERTER RELAY Front view of wire harness connector: |
T17-1 (+B) - Body ground | Always | 11 to 14 V |
| T17-6 (GND) - Body ground | Always | Below 1 Ω | |
| TOWING CONVERTER RELAY Component with harness connected: |
T17-9 (LTIN) - Body ground | Turn signal switch (left turn) off | Below 1 V |
| T17-9 (LTIN) - Body ground | Turn signal switch (left turn) On | 11 to 14 V | |
| T17-3 (RTIN) - Body ground | Turn signal switch (right turn) off | Below 1 V | |
| T17-3 (RTIN) - Body ground | Turn signal switch (right turn) On | 11 to 14 V | |
| T17-4 (LTOT) - Body ground | Turn signal switch (left turn) off | Below 1 V | |
| T17-4 (LTOT) - Body ground | Turn signal switch (left turn) On | 11 to 14 V | |
| T17-4 (LTOT) - Body ground | Turn signal (left turn) off while depressing brake pedal |
Below 1 V | |
| T17-4 (LTOT) - Body ground | Turn signal (left turn) On while depressing brake pedal |
11 to 14 V | |
| T17-4 (LTOT) - Body ground | Brake pedal depressed | 11 to 14 V | |
| T17-2 (RTOT) - Body ground | Turn signal switch (right turn) off | Below 1 V | |
| T17-2 (RTOT) - Body ground | Turn signal switch (right turn) On | 11 to 14 V | |
| T17-2 (RTOT) - Body ground | Turn signal (right turn) off while depressing brake pedal |
Below 1 V | |
| T17-2 (RTOT) - Body ground | Turn signal (right turn) On while depressing brake pedal |
11 to 14 V | |
| T17-2 (RTOT) - Body ground | Brake pedal depressed | 11 to 14 V | |
| T17-8 (STIN) - Body ground | Brake pedal depressed | 11 to 14 V | |
| TOWING BACK-UP RELAY | 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω | ||
| TOWING STOP LAMP RELAY | 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω | ||
| TOWING TAIL RELAY | 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |