RM38G0E _V1 General _100727 SPECIFICATIONS _0502417 F33A-FTV EMISSION CONTROL F
SPECIFICATIONS F33A-FTV EMISSION CONTROL SERVICE DATA
EXHAUST GAS TEMPERATURE SENSOR (for DPF)
| Item |
Tester Connection |
Sensor Temperature |
Specified Condition |
| EXHAUST GAS TEMPERATURE SENSOR |
1 (E2) - 2 (THC3) |
40 to 60°C (104 to 122°F) |
42.1 to 68.4 kΩ |
| NO. 2 EXHAUST GAS TEMPERATURE SENSOR |
1 (E2) - 2 (THCI) |
40 to 60°C (104 to 122°F) |
42.1 to 68.4 kΩ |
| NO. 3 EXHAUST GAS TEMPERATURE SENSOR |
1 (E2) - 2 (THCO) |
40 to 60°C (104 to 122°F) |
42.1 to 68.4 kΩ |
EXHAUST GAS TEMPERATURE SENSOR (for Urea SCR System)
| Tester Connection |
Sensor Temperature |
Specified Condition |
| 1 (E2) - 2 (THSO) |
40 to 60°C (104 to 122°F) |
42.1 to 68.4 kΩ |
EXHAUST GAS TEMPERATURE SENSOR (for EGR)
| Tester Connection |
Sensor Temperature |
Specified Condition |
| 1 (E2) - 2 (THEG) |
40 to 60°C (104 to 122°F) |
7.90 to 12.1 kΩ |
EXHAUST FUEL ADDITION INJECTOR
| Tester Connection |
Condition |
Specified Condition |
| 1 (FIV) - 2 (+B) |
20°C (68°F) |
11.6 to 12.4 Ω |
DPF SWITCH
| Tester Connection |
Condition |
Specified Condition |
| 2 (E) - 5 (B) |
Switch OFF |
10 kΩ or higher |
| 2 (E) - 5 (B) |
Switch ON |
Below 1 Ω |
6 (ILL+) - Battery positive (+) 1 (ILL-) - Battery negative (-) |
- |
Illumination on |
UREA INJECTOR
| Tester Connection |
Condition |
Specified Condition |
| 1 (#1U) - 2 (+B) |
20°C (68°F) |
11.6 to 12.4 Ω |
UREA TANK
| Item |
Specified Condition |
| Urea solution (AdBlue) capacity (Urea tank + filler pipe) |
Approximately 17.9 liters (18.9 US qts, 15.8 Imp. qts) |