OUTLINE
The cooling system is a pressurized, forced-circulation type.
A pressurized radiator reserve tank assembly is used to prevent the engine coolant from deteriorating upon contact with external air.
A coupling fan (fluid coupling assembly) is used to effect linear control.
A thermostat with a bypass valve is located on the water inlet housing to maintain suitable temperature distribution in the cooling system.
EGR cooler to cool down intake air temperature during EGR operation is used.
TOYOTA genuine Super Long Life Coolant (SLLC) is used.
SPECIFICATION
| Engine Coolant | Type | TOYOTA Genuine Super Long Life Coolant (SLLC) or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite and non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of low phosphates and organic acids.) Do not use plain water alone. | |
| Color | Pink | ||
| Maintenance Intervals | First time | 160,000 km (100,000 miles) | |
| Subsequent | Every 80,000 km (50,000 miles) | ||
SLLC is pre-mixed (50% coolant and 50% deionized water). Therefore, no dilution is needed when SLLC in the vehicle is added or replaced.
| Thermostat Opening Temperature | 74 to 78°C (165 to 172°F) |