Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
NM25T0E _58 Vehicle Interior _030589 HEATING / AIR CONDITIONING _0137729 AIR CONDITIONING SYSTEM DE DETAILS F

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  DETAILS  COOLER CONDENSER  


CONSTRUCTION


a.

A sub-cool condenser is used. This is a multi-flow condenser consisting of 3 portions: a condensing portion, a super-cooling portion and a gas-liquid separator (modulator) all integrated together. This cooler condenser assembly uses a sub-cool cycle for its cooling cycle system to improve heat-exchanging efficiency.


b.

In the sub-cool cycle, after the refrigerant passes through the condensing portion of the cooler condenser assembly, both the liquid refrigerant and the gaseous refrigerant that could not be liquefied are cooled again in the super-cooling portion. Thus, the refrigerant is sent to the No. 1 cooler evaporator sub-assembly in an almost completely liquefied state.

1HZ Engine
Y168976C01
5.146,1.083 5.677,0.729 true 1.396,1.75 1.979,1.979 true 2.354,3.25 1.802,3.542 true 5.719,0.542 6.031,0.698 0.313,0.156 10 false *1 1.229,1.604 1.542,1.76 0.313,0.156 10 false *2 1.635,3.448 1.948,3.604 0.313,0.156 10 false *3
*1 Condensing Portion *2 Modulator
*3 Super-cooling Portion - -
V100135

Gaseous Refrigerant
V100136

Liquid Refrigerant


1GR-FE Engine and 1VD-FTV Engine
Y173580C01
1.292,2.188 1.927,2 true 1.906,3.604 2.292,3.271 true 5.115,0.896 5.688,0.417 true 5.698,0.271 6.01,0.427 0.313,0.156 10 false *1 1.135,2.115 1.448,2.271 0.313,0.156 10 false *2 1.76,3.563 2.073,3.719 0.313,0.156 10 false *3
*1 Condensing Portion *2 Modulator
*3 Super-cooling Portion - -
V100135

Gaseous Refrigerant
V100136

Liquid Refrigerant


HINT:

The point at which the air bubbles disappear in the refrigerant of the sub-cool cycle is lower than the proper amount of refrigerant with which the system must be filled. Therefore, if the system is recharged with refrigerant based on the point at which the air bubbles disappear, the amount of refrigerant would be insufficient. As a result, the cooling performance of the system will be affected. If the system is overcharged with refrigerant, this will also lead to reduced performance. For the proper method of verifying the amount of the refrigerant and to recharge the system with refrigerant, refer to the Repair Manual.


Y100972E09
3.688,1.177 3.688,0.438 3.688,0.438 3.844,0.438 false 0.927,1.167 1.823,1.344 0.896,0.177 10 false High Pressure 3.906,0.365 5.677,0.542 1.771,0.177 10 false Properly Recharged Amount 2.927,1.875 5.021,2.052 2.094,0.177 10 false Point at which Bubbles Disappear 2.938,2.396 4.313,2.573 1.375,0.177 10 false Amount of Refrigerant