16361A 1.INSPECT FAN AND GENERATOR V BELT
| *a | CORRECT |
| *b | INCORRECT |
Check the fan and generator V belt for wear, cracks or other signs of damage.
If any of the following defects is found, replace the fan and generator V belt.
The fan and generator V belt is cracked.
The fan and generator V belt is worn out to the extent that the cords are exposed.
The fan and generator V belt has chunks missing from the ribs.
Check by hand that the fan and generator V belt fits properly in the ribbed grooves and has not slipped out of the grooves on the bottom of the crankshaft pulley. Then run the engine for 5 minutes or more and recheck the tension.
16620D 2.INSPECT V-RIBBED BELT TENSIONER ASSEMBLY
Turn the V-ribbed belt tensioner assembly clockwise and counterclockwise. Check that the V-ribbed belt tensioner assembly moves smoothly.
If a malfunction exists, replace the V-ribbed belt tensioner assembly.