77740 1.INSPECT CHARCOAL CANISTER ASSEMBLY
Visually check the charcoal canister assembly for cracks or damage.
If cracks or damage are found, replace the charcoal canister assembly.
| *a | Port A |
| *b | Port B |
| *c | Port C |
Using SST, inspect the charcoal canister assembly.
| Condition | Specified Condition |
|---|---|
| Close ports B and C, and then apply vacuum to port A (1.96 kPa (15 mmHg, 0.579 in.Hg)) | No leak |
| Close port C, and then blow air into port A (4.71 kPa (0.05 kgf/cm2, 0.7 psi)) | Air flows from port B |
| Blow air into port A (4.71 kPa (0.05 kgf/cm2, 0.7 psi)) | Air flows from both ports B and C |
| Close port C, and then apply vacuum to port A (1.96 kPa (15 mmHg, 0.579 in.Hg)) | Air flows from port B |
If the result is not as specified, replace the charcoal canister assembly.