17650G 1.INSPECT PURGE VSV
Inspect the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 23 to 26 Ω |
| 1 - Body ground | Always | 10 MΩ or higher |
| 2 - Body ground |
If the result is not as specified, replace the purge VSV.
Check the operation of the purge VSV.
| *a | Port F |
| *b | Port E |
| *c | Does not flow |
| *d | Air |
Check that air does not flow from port F when air is applied to port E.
| *a | Port F |
| *b | Port E |
| *c | Air |
Apply battery voltage to the connector and check the purge VSV operation.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 1 Battery negative (-) → Terminal 2 |
Air flows from port E to port F |
If the result is not as specified, replace the purge VSV.