Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
RM25T0E _58 Vehicle Interior _029469 HEATING / AIR CONDITIONING _0133768 AIR CONDITIONING SYSTEM L

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  PRECAUTION  


NOTICE:

Following precautions for w/ air conditioning system.


IF ANY OF FOLLOWING CONDITIONS ARE MET, KEEP ENGINE IDLING (ENGINE SPEED AT LESS THAN 2000 RPM) WITH AIR CONDITIONING SWITCH ON FOR AT LEAST 2 MINUTES


·

Refrigerant gas has been refilled or parts of the air conditioning system have been replaced.

·

The engine has not been started for a long time.


NOTICE:

If the engine speed is more than 2000 rpm, the cooler compressor assembly may be damaged.



DO NOT HANDLE REFRIGERANT IN AN ENCLOSED AREA OR NEAR AN OPEN FLAME


AC02810


ALWAYS WEAR EYE PROTECTION



BE CAREFUL NOT TO GET LIQUID REFRIGERANT IN YOUR EYES OR ON YOUR SKIN


AC02811

If liquid refrigerant gets in your eyes or on your skin:

a.

Wash the area with lots of cold water.

CAUTION:

Do not rub your eyes or skin.



b.

Apply clean petroleum jelly to the skin.


c.

Go immediately to a hospital or see a physician for professional treatment.



NEVER HEAT CONTAINER OR EXPOSE IT TO OPEN FLAME



BE CAREFUL NOT TO DROP CONTAINER OR APPLY PHYSICAL SHOCKS TO IT



DO NOT OPERATE COMPRESSOR WITH INSUFFICIENT REFRIGERANT IN REFRIGERANT SYSTEM


a.

If there is not enough refrigerant in the refrigerant system, oil lubrication will be insufficient and compressor burnout may occur. Necessary care should be taken to avoid this.



DO NOT OPEN HIGH PRESSURE MANIFOLD VALVE WHILE COMPRESSOR IS OPERATING


N011084C16
2.25,0.052 2.458,0.25 0.208,0.198 10 *b 1.458,0.063 1.677,0.26 0.219,0.198 10 *a 1.344,0.75 1.49,0.875 0.146,0.125 6 LO 1.667,0.76 1.781,0.885 0.115,0.125 6 HI 2.146,0.76 2.292,0.885 0.146,0.125 6 LO 2.49,0.76 2.604,0.885 0.115,0.125 6 HI
*a Incorrect
*b Correct


a.

Open and close only the low pressure valve.

If the high pressure valve is opened, refrigerant flows in the reverse direction causing the charging cylinder to rupture.



BE CAREFUL NOT TO OVERCHARGE SYSTEM WITH REFRIGERANT


a.

If the refrigerant is overcharged, it causes problems such as insufficient cooling, poor fuel economy and engine overheating.



DO NOT OPERATE ENGINE AND COOLER COMPRESSOR ASSEMBLY WITHOUT REFRIGERANT


CAUTION:

Doing so may damage inside the compressor because the compressor parts always move regardless of whether the air conditioning system is turned on or off.



GENERAL PRECAUTION


a.

While using the battery during inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.