CHECK COOLER STABILIZER AMPLIFIER ASSEMBLY (for 1HZ)
Measure the voltage according to the value(s) in the table below.
Check from the rear of the connector while it is connected to the cooler stabilizer amplifier assembly.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| I11-3 (PSW) - I11-16(GND) | R-B - W-B | Pressure switch signal | Ignition switch ON Blower switch ON Refrigerant pressure: Normal pressure (less than 3.14 MPa [32.0 kgf/cm2, 455 psi] and more than 0.196 MPa [2.0 kgf/cm2, 28 psi]) |
11 to 14 V |
| Ignition switch ON Blower switch ON Refrigerant pressure: Abnormal pressure (less than 0.196 MPa [2.0 kgf/cm2, 28 psi] or more than 3.14 MPa [32.0 kgf/cm2, 455 psi]) |
Below 1 V | |||
| I11-11 (B) - I11-16 (GND) | L-R - W-B | Ignition power supply | Ignition switch ON Blower switch ON |
11 to 14 V |
| Ignition switch off | Below 1 V | |||
| I11-16 (GND) - Body ground | W-B - Body ground | Ground for main power supply | Always | Below 1 V |
| I11-20 (MGC) - I11-16 (GND) | L - W-B | Magnet clutch assembly operation signal | Ignition switch ON Blower switch ON A/C switch OFF Magnet clutch relay is not engaged |
11 to 14 V |
| Ignition switch ON Blower switch ON A/C switch ON Magnet clutch relay is engaged |
Below 1 V | |||
| I11-15 (SG) - Body ground | B-L - Body ground | Ground for No. 1 cooler thermistor (evaporator temperature sensor) | Always | Below 1 V |
| I11-7 (TE) - I11-15 (SG) | Y-G - B-L | No. 1 cooler thermistor (evaporator temperature sensor) signal | Ignition switch ON Blower switch ON Evaporator temperature at 0°C (32°F) Temperature control resistor MIN Cool |
1.8 to 2.2 V |
| Ignition switch ON Blower switch ON Evaporator temperature at 15°C (59°F) Temperature control resistor MIN Cool |
1.0 to 1.4 V | |||
| I11-10 (ST) - I11-16 (GND) | B-W - W-B | Starter switch cut signal | Engine start | 11 to 14 V |
| I11-8 (B/V) - I11-7 (TE) | Y-B - Y-G | Temperature control resistor signal | Ignition switch ON Blower switch ON Terminals between TE and SG connected Temperature control resistor OFF |
2.0 to 2.4 V |
| Ignition switch ON Blower switch ON Terminals between TE and SG connected Temperature control resistor MAX Cool |
Below 1 V | |||
| Ignition switch ON Blower switch ON Terminals between TE and SG connected Temperature control resistor MIN Cool |
1.0 to 1.4 V |
CHECK COOLER STABILIZER AMPLIFIER ASSEMBLY (for 1VD-FTV and 1GR-FE)
Measure the voltage according to the value(s) in the table below.
Check from the rear of the connector while it is connected to the cooler stabilizer amplifier assembly.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| I12-2 (PSW) - I12-5(GND) | R-B - W-B | Pressure switch signal | Ignition switch ON Blower switch ON Refrigerant pressure: Normal pressure (less than 3.14 MPa [32.0 kgf/cm2, 455 psi] and more than 0.196 MPa [2.0 kgf/cm2, 28 psi]) |
11 to 14 V |
| Ignition switch ON Blower switch ON Refrigerant pressure: Abnormal pressure (less than 0.196 MPa [2.0 kgf/cm2, 28 psi] or more than 3.14 MPa [32.0 kgf/cm2, 455 psi]) |
Below 1 V | |||
| I12-7 (B) - I12-5 (GND) | L-R - W-B | Ignition power supply | Ignition switch ON Blower switch ON |
11 to 14 V |
| Ignition switch off | Below 1 V | |||
| I12-5 (GND) - Body ground | W-B - Body ground | Ground for main power supply | Always | Below 1 V |
| I12-11 (MGC) - I12-5 (GND) | L - W-B | Magnet clutch assembly operation signal | Ignition switch ON Blower switch ON A/C switch OFF Magnet clutch relay is not engaged |
11 to 14 V |
| Ignition switch ON Blower switch ON A/C switch ON Magnet clutch relay is engaged |
Below 1 V | |||
| I12-6 (ACT) - I12-5 (GND) | L-B - W-B | Cooler compressor assembly on permit signal | Ignition switch ON A/C switch ON Blower switch ON Engine is running Magnet clutch relay is not engaged |
Below 1 V |
| I12-12 (SG) - Body ground | W-G - Body ground | Ground for No. 1 cooler thermistor (evaporator temperature sensor) | Always | Below 1 V |
| I12-3 (TE) - I12-12 (SG) | Y-G - W-G | No. 1 cooler thermistor (evaporator temperature sensor) signal | Ignition switch ON Blower switch ON Evaporator temperature at 0°C (32°F) Temperature control resistor MIN Cool |
1.8 to 2.2 V |
| Ignition switch ON Blower switch ON Evaporator temperature at 15°C (59°F) Temperature control resistor MIN Cool |
1.0 to 1.4 V | |||
| I12-1 (AC1) - I12-5 (GND) | B-W - W-B | Idle-up request signal | Ignition switch ON Blower switch ON Magnet clutch is not engaged A/C switch OFF |
11 to 14 V |
| Ignition switch ON Blower switch ON Magnet clutch is engaged A/C switch ON |
Below 1 V | |||
| I12-4 (IGN) - I12-5 (GND) | B - W-B | Engine speed signal | Engine is running Blower switch ON |
Pulse generation |
| I12-10 (LOCK) - I12-12(SG) | B-W - W-G | Cooler compressor assembly lock sensor signal | Engine is running Blower switch ON Magnet clutch is engaged |
Pulse generation |
| I12-8 (B/V) - I12-3 (TE) | Y-B - Y-G | Temperature control resistor signal | Ignition switch ON Blower switch ON Terminals between TE and SG connected Temperature control resistor OFF |
2.0 to 2.4 V |
| Ignition switch ON Blower switch ON Terminals between TE and SG connected Temperature control resistor MAX Cool |
Below 1 V | |||
| Ignition switch ON Blower switch ON Terminals between TE and SG connected Temperature control resistor MIN Cool |
1.0 to 1.4 V |