Home › Engine / Hybrid System › 1HZ (COOLING) › RADIATOR
RM25T0E _51 Engine / Hybrid System _029524 1HZ COOLING _0133827 RADIATOR G

1HZ COOLING  RADIATOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 16401 1.INSPECT RADIATOR CAP

a.

Measure the valve opening pressure.

i.
A253809N01
0.389,1.294 0.494,1.469 0.105,0.175 10 1 0.525,1.589 0.63,1.764 0.105,0.175 10 2 0.931,1.788 1.036,1.963 0.105,0.175 10 3

If there are water stains or foreign matter on rubber packing 1, 2 or 3, clean it by using water and finger scouring.


ii.

Check that rubber packing 1 and 2 are not deformed, cracked or swollen.


iii.

Check that rubber packing 2 and 3 are not stuck together.


iv.

Apply engine coolant to rubber packing 2.


v.
A320067C01
0.5,0.302 0.667,0.167 0.667,0.167 0.833,0.167 false 1.583,0.75 1.833,0.5 1.833,0.5 2,0.5 false 0.854,0.083 1.167,0.24 0.313,0.156 10 false *1 1.802,1.104 2.052,1.271 0.25,0.167 10 true *a 2.021,0.417 2.333,0.573 0.313,0.156 10 false *b
*1 Radiator Cap
*a 30° or more
*b Radiator Cap Tester


Prepare a radiator cap tester, and tilt it 30° or higher.


vi.

Pump the radiator cap tester several times, and check the maximum pressure*.

Pumping speed:

1 pump per second


HINT:

*: Even if the cap cannot maintain the maximum pressure, it is not a defect.


Standard Judgment Criterion:
Item Specified Condition
Standard value
(for brand-new cap)
93 to 123 kPa (0.9 to 1.3 kgf/cm2, 13.5 to 18 psi)
Minimum standard value
(after using cap)
79 kPa (0.8 kgf/cm2, 11.4 psi)


If the maximum pressure is less than the minimum standard value, replace the radiator cap.



Hide 16400 2.INSPECT FINS FOR BLOCKAGE

a.

Check that the radiator and condenser are not blocked with leaves, dirt, or insects. Clean the hose connections.

If the fins are blocked, wash them with water or a steam cleaner.

NOTICE:
·

If the distance between the steam cleaner and core is too close, the fins may be damaged.

·

Keep the following injection distance.

Standard Injection Distance:
Injection Pressure Injection Distance
2942 to 4903 kPa (30.0 to 50.0 kgf/cm2, 427 to 711 psi) 300 mm (11.8 in.)
4903 to 7845 kPa (50.0 to 80.0 kgf/cm2, 711 to 1138 psi) 500 mm (19.7 in.)


·

If the fins are bent, straighten them with a screwdriver or pliers.

·

Never apply water directly onto the electric components.




b.

Dry the fins with compressed air.