25850 1.INSPECT ELECTRIC VACUUM REGULATING VALVE ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 11 to 13 Ω |
| 1 - Body ground | Always | 10 MΩ or higher |
| 2 - Body ground |
If the result is not as specified, replace the electric vacuum regulating valve assembly.
Inspect the electric vacuum regulating valve assembly operation.
| *a | Port A |
| *b | Filter |
| *c | Air |
Check that air flows from port A to the filter.
| *a | Port A |
| *b | Port B |
| *c | Air |
| *d | Battery |
| *e | Terminal 1 |
| *f | Terminal 2 |
Apply battery voltage to the connector, and check electric vacuum regulating valve assembly operation.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 1 Battery positive (-) → Terminal 2 |
Air flows from port A to port B |
If the result is not as specified, replace the electric vacuum regulating valve assembly.