27330 1.INSPECT GENERATOR ROTOR ASSEMBLY
| *a | Slip Ring |
Check the generator rotor assembly for an open circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Slip ring - Slip ring | 20°C (68°F) | 11.6 to 12.4 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Slip ring - Slip ring | 20°C (68°F) | 2.1 to 2.5 Ω |
If the result is not as specified, replace the generator rotor assembly.
| *a | Slip Ring |
| *b | Rotor Core |
Check if the generator rotor assembly is grounded.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Slip ring - Rotor core | Always | 10 MΩ or higher |
If the result is not as specified, replace the generator rotor assembly.
Check that the slip rings are not rough or scored.
If they are rough or scored, replace the generator rotor assembly.
| *a | Diameter |
Using a vernier caliper, measure the slip ring diameter.
14.2 to 14.8 mm (0.559 to 0.583 in.)
14.0 mm (0.551 in.)
If the diameter is less than the minimum, replace the generator rotor assembly.
Inspect the generator rotor bearing.
Check that the generator rotor bearing is not rough or worn.
If necessary, replace the generator rotor assembly.
2.INSPECT GENERATOR DRIVE END FRAME
| *a | Coil Lead |
Check the stator for an open circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Coil lead - Coil lead | Always | Below 1 Ω |
If the result is not as specified, replace the generator assembly.
| *a | Coil Lead |
| *b | Drive End Frame |
Check the stator for a short circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Coil lead - Generator drive end frame | Always | 10 kΩ or higher |
If the result is not as specified, replace the generator assembly.
Inspect the generator drive end frame bearing.
If the result is not as specified, replace the generator assembly.
27370 3.INSPECT GENERATOR BRUSH HOLDER ASSEMBLY
| *a | Diameter |
Using a vernier caliper, measure the exposed brush length.
9.5 to 11.5 mm (0.374 to 0.453 in.)
4.5 mm (0.177 in.)
If the exposed length is less than the minimum, replace the generator brush holder assembly.
27357 4.INSPECT GENERATOR HOLDER WITH RECTIFIER
| *a | Positive (+) Terminal |
| *b | Rectifier Terminal |
Check the positive terminal of the generator holder with rectifier.
Using an ohmmeter, connect one tester probe to the positive (+) terminal and the other to each rectifier terminal.
Reverse the polarity of the tester probes and repeat the step above.
Check that one polarity shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher.
If the result is not as specified, replace the generator holder with rectifier.
| *a | Negative (-) Terminal |
Check the negative terminal of the generator holder with rectifier.
Using an ohmmeter, connect one tester probe to the negative (-) terminal and the other to each rectifier terminal.
Reverse the polarity of the tester probes and repeat the step above.
Check that one polarity shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher.
If the result is not as specified, replace the generator holder with rectifier.
27700A 5.INSPECT GENERATOR REGULATOR ASSEMBLY
| *a | Terminal F |
| *b | Terminal B |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Terminal F - Terminal B | Always | Below 1 Ω or higher than 10 kΩ |
If the result is not as specified, replace the generator regulator assembly.
When the ohmmeter leads are initially touched to the generator regulator assembly, one of the above values is output.
When the leads are reversed, the reading changes to the other value.
| *a | Terminal F |
| *b | Terminal E |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Terminal F - Terminal E | Always | Below 1 Ω or higher than 10 kΩ |
If the result is not as specified, replace the generator regulator assembly.
When the ohmmeter leads are initially touched to the generator regulator assembly, one of the above values is output.
When the leads are reversed, the reading changes to the other value.