Home › Power Source / Network › 1HZ (BATTERY / CHARGING) › GENERATOR
RM25T0E _57 Power Source / Network _029611 1HZ BATTERY / CHARGING _0134068 GENERATOR G

1HZ BATTERY / CHARGING  GENERATOR  INSPECTION  


PROCEDURE

Hide 27330 1.INSPECT GENERATOR ROTOR ASSEMBLY

a.
A330334C01
2.635,1.865 2.354,1.865 2.354,1.865 2.042,1.448 false 2.698,1.781 3.01,1.938 0.313,0.156 10 false *a
*a Slip Ring


Check the generator rotor assembly for an open circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
for 30 A Type:
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 11.6 to 12.4 Ω

for 80 A Type:
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 2.1 to 2.5 Ω


If the result is not as specified, replace the generator rotor assembly.



b.
A220277C01
1.604,0.99 1.99,0.396 1.99,0.396 2.208,0.396 true 1.99,1.563 2.49,0.708 2.49,0.708 2.729,0.708 false 2.781,0.635 3.094,0.792 0.313,0.156 10 false *a 2.25,0.323 2.563,0.479 0.313,0.156 10 false *b
*a Slip Ring
*b Rotor Core


Check if the generator rotor assembly is grounded.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance
Tester Connection Condition Specified Condition
Slip ring - Rotor core Always 10 MΩ or higher

If the result is not as specified, replace the generator rotor assembly.



c.

Check that the slip rings are not rough or scored.

If they are rough or scored, replace the generator rotor assembly.


d.
A220278C01
0.552,0.604 0.865,0.76 0.313,0.156 10 false *a
*a Diameter


Using a vernier caliper, measure the slip ring diameter.

Standard diameter:

14.2 to 14.8 mm (0.559 to 0.583 in.)


Minimum diameter:

14.0 mm (0.551 in.)


If the diameter is less than the minimum, replace the generator rotor assembly.


e.

Inspect the generator rotor bearing.

i.

Check that the generator rotor bearing is not rough or worn.

If necessary, replace the generator rotor assembly.



Hide 2.INSPECT GENERATOR DRIVE END FRAME

a.
A330273C01
2.615,1.021 2.75,0.167 2.75,0.167 3,0.167 true 2.469,0.365 2.5,0.167 2.5,0.167 2.833,0.167 false 3.021,0.094 3.333,0.25 0.313,0.156 10 false *a
*a Coil Lead


Check the stator for an open circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance
Tester Connection Condition Specified Condition
Coil lead - Coil lead Always Below 1 Ω

If the result is not as specified, replace the generator assembly.



b.
A330274C01
2.5,0.417 2.667,0.167 2.667,0.167 2.833,0.167 false 0.917,1.333 1.083,1.333 1.083,1.333 1.302,1.5 false 2.865,0.094 3.177,0.25 0.313,0.156 10 false *a 0.771,1.25 1.083,1.406 0.313,0.156 10 false *b
*a Coil Lead
*b Drive End Frame


Check the stator for a short circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance
Tester Connection Condition Specified Condition
Coil lead - Generator drive end frame Always 10 kΩ or higher

If the result is not as specified, replace the generator assembly.



c.

Inspect the generator drive end frame bearing.

i.

If the result is not as specified, replace the generator assembly.



Hide 27370 3.INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

a.
A330338C01
0.969,0.906 1.281,1.063 0.313,0.156 10 false *a
*a Diameter


Using a vernier caliper, measure the exposed brush length.

Standard exposed length:

9.5 to 11.5 mm (0.374 to 0.453 in.)


Minimum exposed length:

4.5 mm (0.177 in.)


If the exposed length is less than the minimum, replace the generator brush holder assembly.


Hide 27357 4.INSPECT GENERATOR HOLDER WITH RECTIFIER

a.
A330275C01
2.198,1.115 2.583,0.667 2.583,0.667 2.75,0.667 false 0.917,0.667 1.083,0.667 1.083,0.667 1.917,0.833 false 0.771,0.594 1.083,0.75 0.313,0.156 10 false *a 2.771,0.583 3.083,0.74 0.313,0.156 10 false *b
*a Positive (+) Terminal
*b Rectifier Terminal


Check the positive terminal of the generator holder with rectifier.

i.

Using an ohmmeter, connect one tester probe to the positive (+) terminal and the other to each rectifier terminal.


ii.

Reverse the polarity of the tester probes and repeat the step above.


iii.

Check that one polarity shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher.

If the result is not as specified, replace the generator holder with rectifier.



b.
A330276C01
1.563,1.156 1.333,0.417 1.333,0.417 1.167,0.417 true 1.01,0.333 1.323,0.49 0.313,0.156 10 false *a
*a Negative (-) Terminal


Check the negative terminal of the generator holder with rectifier.

i.

Using an ohmmeter, connect one tester probe to the negative (-) terminal and the other to each rectifier terminal.


ii.

Reverse the polarity of the tester probes and repeat the step above.


iii.

Check that one polarity shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher.

If the result is not as specified, replace the generator holder with rectifier.



Hide 27700A 5.INSPECT GENERATOR REGULATOR ASSEMBLY

a.
A220284C01
0.917,1.594 1.104,1.594 1.104,1.594 1.656,1.031 true 2.677,1.75 2.521,1.75 2.521,1.75 2.24,1.333 true 0.74,1.5 1.052,1.656 0.313,0.156 10 false *a 2.729,1.677 3.042,1.833 0.313,0.156 10 false *b
*a Terminal F
*b Terminal B


Measure the resistance according to the value(s) in the table below.

Standard Resistance
Tester Connection Condition Specified Condition
Terminal F - Terminal B Always Below 1 Ω or higher than 10 kΩ

If the result is not as specified, replace the generator regulator assembly.

HINT:

When the ohmmeter leads are initially touched to the generator regulator assembly, one of the above values is output.

When the leads are reversed, the reading changes to the other value.



b.
A220285C01
0.75,1.083 0.875,1.552 0.875,1.552 1.01,1.552 true 1.813,1.042 1.99,1.552 1.99,1.552 2.146,1.552 true 2.177,1.469 2.49,1.625 0.313,0.156 10 false *a 1.052,1.469 1.365,1.625 0.313,0.156 10 false *b
*a Terminal F
*b Terminal E


Measure the resistance according to the value(s) in the table below.

Standard Resistance
Tester Connection Condition Specified Condition
Terminal F - Terminal E Always Below 1 Ω or higher than 10 kΩ

If the result is not as specified, replace the generator regulator assembly.

HINT:

When the ohmmeter leads are initially touched to the generator regulator assembly, one of the above values is output.

When the leads are reversed, the reading changes to the other value.