Home › Power Source / Network › 1HZ (BATTERY / CHARGING) › GENERATOR
RM25T0E _57 Power Source / Network _029611 1HZ BATTERY / CHARGING _0134068 GENERATOR A

1HZ BATTERY / CHARGING  GENERATOR  REASSEMBLY  


PROCEDURE

Hide 27330 1.INSTALL GENERATOR ROTOR ASSEMBLY

a.
A330277N01
1.167,0.25 1.333,0.25 1.333,0.25 1.604,0.635 false 0.885,0.167 1.344,0.365 0.458,0.198 10 false SST

Using SST and a press, press in the generator rotor assembly.

SST
09285-76010  


b.

Place the generator washer on the generator rotor assembly.


Hide 2.INSTALL GENERATOR RECTIFIER END FRAME

a.
A330278C01
1.844,0.76 2.417,0.25 2.417,0.25 2.583,0.25 true 2.615,0.177 2.927,0.333 0.313,0.156 10 false *a
*a 17 mm Socket Wrench


Using a 17 mm socket wrench and press, slowly press on the generator rectifier end frame.


b.
A337330C01
2.406,0.417 2.583,0.25 2.583,0.25 2.75,0.25 false 2.792,0.156 3.104,0.313 0.313,0.156 10 false *a
*a Cord Clip
V100135

Nut A
V100136

Nut B


Install the cord clip and 4 nuts.

Torque:
for nut A : 5.4 N*m (55 kgf*cm, 48 in.*lbf)
for nut B : 4.5 N*m (46 kgf*cm, 40 in.*lbf)


Hide 27357 3.INSTALL GENERATOR HOLDER WITH RECTIFIER

a.
A330279C01
2.354,0.198 2.667,0.354 0.313,0.156 10 false *a
*a Inside


Install the 4 rubber insulators to the lead wires.

NOTICE:

Be careful to install the rubber insulators in the correct direction.



b.
A330280C01
0,0 0,0 false
V100135

Push


While pushing down on the generator holder with rectifier, install it with the 4 screws.

Torque:
2.9 N*m (30 kgf*cm, 26 in.*lbf)


Hide 27700A 4.INSTALL GENERATOR REGULATOR ASSEMBLY

a.

Install the generator regulator assembly with the 3 screws.

Torque:
2.0 N*m (20 kgf*cm, 18 in.*lbf)


Hide 27370 5.INSTALL GENERATOR BRUSH HOLDER ASSEMBLY

a.

Install the plate seal.


b.
A330281C01
0,0 0,0 false
V100135

Upper


Install the generator brush holder assembly with the 2 screws.

Torque:
2.0 N*m (20 kgf*cm, 18 in.*lbf)


c.

Install the brush holder cover.


Hide 27039 6.INSTALL GENERATOR REAR END COVER

a.
A330282C01
2.333,0.167 2.5,0.167 2.5,0.167 2.698,0.635 false 2.167,0.094 2.479,0.25 0.313,0.156 10 false *a
*a Rectifier Plate


Install the generator rear end cover and rectifier plate with the bolt and 3 nuts.

Torque:
for nut : 4.4 N*m (45 kgf*cm, 39 in.*lbf)
for bolt : 3.9 N*m (40 kgf*cm, 35 in.*lbf)


b.

Install the terminal insulator with the nut.

Torque:
4.1 N*m (42 kgf*cm, 36 in.*lbf)


Hide 27411 7.INSTALL GENERATOR PULLEY

a.

Temporarily install the generator pulley with the generator pulley nut by hand.


b.
A327040C01
2.5,1.469 2.5,1.302 2.5,1.302 2.917,0.75 true 3.135,1.333 3.135,0.667 true 1.729,1.885 1.958,2.042 0.229,0.156 10 false *a 2.854,1.344 3.406,1.49 0.552,0.146 10 false SST 1-A 2.25,1.49 2.802,1.635 0.552,0.146 10 true SST 1-B
*a Hold
V100135

Turn


Mount the generator assembly in a vise between aluminum plates.


c.

Install SST 1-A to the generator pulley shaft.

SST
09820-63011  (09820-06010, 09820-06021)

HINT:
SST 1-A and 1-B 09820-06010
SST 2 09820-06021



d.

Install SST 1-B to SST 1-A.


e.

Hold SST 1-A with a torque wrench and turn SST 1-B clockwise with the specified torque.

Torque:
39 N*m (398 kgf*cm, 29 ft.*lbf)

NOTICE:

Make sure that SST is secured to the generator rotor shaft.



f.
A327041C01
2.708,0.76 2.542,0.427 2.542,0.427 2.375,0.427 false 1.948,0.344 2.385,0.542 0.438,0.198 10 false SST 2
V100135

Insert


Insert SST 2 and attach it to the generator pulley nut.


g.
A327044C01
1.427,1.688 1.74,1.844 0.313,0.156 10 false *a
*a Hold
V100135

Turn


Tighten the generator pulley nut by turning SST 1-A in the direction shown in the illustration.

Torque:
133 N*m (1356 kgf*cm, 98 ft.*lbf)


h.

Remove SST 2 from the generator assembly.


i.
A327043C01
2.667,1.5 2.667,1.333 2.667,1.333 2.917,0.698 true 3.125,1.292 3.125,0.625 true 1.958,1.521 2.177,1.708 0.219,0.188 10 true *a 2.833,1.281 3.427,1.469 0.594,0.188 10 false SST 1-A 2.396,1.521 2.969,1.719 0.573,0.198 10 true SST 1-B
*a Hold
V100135

Turn


Turn SST 1-B in the direction shown in the illustration and remove SST 1-A and 1-B.


j.

Turn the generator pulley and check that the generator pulley moves smoothly.