Home › Power Source / Network › 1VD-FTV (BATTERY / CHARGING) › GENERATOR
RM25T0E _57 Power Source / Network _029610 1VD-FTV BATTERY / CHARGING _0134070 GENERATOR G

1VD-FTV BATTERY / CHARGING  GENERATOR  INSPECTION  


PROCEDURE

Hide 27330 1.INSPECT GENERATOR ROTOR ASSEMBLY

a.

Check that the slip rings are not rough or scored.

If rough or scored, replace the generator rotor assembly.


b.
A156436C01
1.25,1.833 1.615,1.833 false 1.521,1.833 1.656,1.479 false 1.625,1.833 1.76,1.438 false 1.104,1.74 1.417,1.896 0.313,0.156 10 false *a
*a Slip Ring


Check the rotor for an open circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 2.3 to 2.7 Ω

If the result is not as specified, replace the generator rotor assembly.



c.
A156437C01
1.458,1.729 1.625,1.729 1.625,1.729 1.667,1.49 false 3.073,0.25 2.906,0.25 2.906,0.25 2.792,1.177 true 1.281,1.625 1.594,1.781 0.313,0.156 10 false *a 3.104,0.156 3.354,0.313 0.25,0.156 10 false *b
*a Slip Ring
*b Rotor Core


Check if the rotor is grounded.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance
Tester Connection Condition Specified Condition
Slip ring - Rotor core Always 10 MΩ or higher

If the result is not as specified, replace the generator rotor assembly.



d.
A156438C01
0.531,0.531 0.844,0.688 0.313,0.156 10 false *a
*a Diameter


Check the slip ring diameter.

i.

Using a vernier caliper, measure the diameter of each slip ring.

Standard diameter:

14.2 to 14.8 mm (0.559 to 0.583 in.)


Minimum diameter:

14.0 mm (0.551 in.)


If the diameter is less than the minimum, replace the generator rotor assembly.



e.
A163099

Check that the bearing is not rough or worn.

If necessary, replace the generator rotor assembly.


Hide 27370 2.INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

a.
A163020C01
0.802,0.604 1.115,0.76 0.313,0.156 10 false *a
*a Length


Using a vernier caliper, measure the brush length.

Standard length:

9.5 to 11.5 mm (0.374 to 0.453 in.)


Minimum length:

4.5 mm (0.177 in.)


If the brush length is less than the minimum, replace the generator brush holder assembly.