17650 1.INSPECT VACUUM SWITCHING VALVE ASSEMBLY (for EGR Bypass Valve)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 37 to 44 Ω |
| 1 - Body ground 2 - Body ground |
20°C (68°F) | 10 kΩ or higher |
If the result is not as specified, replace the vacuum switching valve assembly.
Check operation of the vacuum switching valve assembly.
| *a | Vacuum |
| *b | Air |
| *c | Port E |
| *d | Port F |
| *e | Filter |
When a vacuum of 67 kPa (500 mmHg, 19.7 in.Hg) is applied to port F, check that air flows from port E to the filter.
| *a | Air |
| *b | Port E |
| *c | Port F |
Apply battery voltage across terminals 1 and 2.
Check that air flows from port E to port F.
If the result is not as specified, replace the vacuum switching valve assembly.