22100 1.INSPECT FUEL SUPPLY PUMP ASSEMBLY
Inspect the suction control valve.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 1.9 to 2.3 Ω |
If the result is not as specified, replace the fuel supply pump assembly.