1.INSPECT FUEL TEMPERATURE SENSOR
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 2.32 to 2.59 kΩ |
| 1 - 2 | 80°C (176°F) | 0.310 to 0.326 kΩ |
When checking the fuel temperature sensor in water, keep the terminals dry. After the check, wipe the sensor dry.
If the result is not as specified, replace the fuel temperature sensor.