Home › Engine / Hybrid System › 1HZ (FUEL) › FUEL TANK SELECT VALVE
RM25T0E _51 Engine / Hybrid System _029893 1HZ FUEL _0136500 FUEL TANK SELECT VALVE A

1HZ FUEL  FUEL TANK SELECT VALVE  INSTALLATION  


PROCEDURE

Hide 77720E 1.INSTALL FUEL TANK SOLENOID RETURN VALVE ASSEMBLY

a.

Install the fuel tank solenoid return valve assembly with the bolt to the fuel solenoid valve main bracket.

Torque:
12.5 N*m (127 kgf*cm, 9 ft.*lbf)


b.

Attach the wire harness clamp.


Hide 77710B 2.INSTALL FUEL TANK SOLENOID MAIN VALVE ASSEMBLY

a.

Install the fuel tank solenoid main valve assembly with the bolt to the fuel solenoid valve main bracket.

Torque:
12.5 N*m (127 kgf*cm, 9 ft.*lbf)


Hide 77406 3.INSTALL FUEL TANK SOLENOID VALVE WITH BRACKET

a.

Install the fuel tank solenoid valve with bracket with the 2 bolts.

Torque:
30 N*m (306 kgf*cm, 22 ft.*lbf)


b.

Connect the fuel tank solenoid return valve connector.


c.

Connect the 3 fuel hoses to the fuel tank solenoid main valve assembly and slide the 3 clamps to secure the hoses.


d.

Connect the 3 fuel hoses to the fuel tank solenoid return valve assembly and slide the 3 clamps to secure the hoses.


e.

Attach the wire harness clamp.


Hide 4.BLEED AIR FROM FUEL SYSTEM