Home › Engine / Hybrid System › 1VD-FTV (COOLING) › RADIATOR
RM25T0E _51 Engine / Hybrid System _029897 1VD-FTV COOLING _0136551 RADIATOR G

1VD-FTV COOLING  RADIATOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 16471B 1.INSPECT RESERVOIR CAP

CAUTION:

Do not remove the reservoir cap while the engine and radiator assembly are still hot. Pressurized hot engine coolant and steam may be released and cause serious burns.


a.

Measure the valve opening pressure.

i.
A326766C01
0.99,1.698 1.281,1.698 true 1.104,1.458 1.479,1.458 true 0.813,1.625 1.125,1.781 0.313,0.156 10 false *1 0.948,1.365 1.26,1.521 0.313,0.156 10 false *2
*1 O-Ring
*2 Rubber Packing


If there are water stains or foreign matter on the O-ring, clean it with water and finger scouring.


ii.

Check that O-ring is not deformed, cracked or swollen.


iii.

Apply engine coolant to the O-ring and rubber packing before using the radiator cap tester.


iv.
A326767C01
0.385,0.521 0.385,0.219 0.385,0.219 0.594,0.219 false 1.531,0.417 1.656,0.26 1.656,0.26 1.865,0.26 false 0.635,0.146 0.948,0.302 0.313,0.156 10 false *1 1.906,0.188 2.219,0.344 0.313,0.156 10 false *a 0.552,1.063 0.865,1.219 0.313,0.156 10 false *b
*1 Reservoir Cap
*a Radiator Cap Tester
*b 30° or more


When using the radiator cap tester, tilt it more than 30° degrees.


v.

Pump the radiator cap tester several times, and check the maximum pressure*.

Pump speed:

1 pump per second


*: Even if the cap cannot maintain the maximum pressure, it is not a defect.

Judgment Criterion:
Item Specified Condition
Standard
(for brand-new cap)
93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi)
Minimum
(after using cap)
79 kPa (0.8 kgf/cm2, 11.4 psi)


If the maximum pressure is less than the minimum, replace the reservoir cap.



Hide 16400 2.INSPECT FINS FOR BLOCKAGE

a.

If the fins are clogged, wash them with water or a steam cleaner and dry them with compressed air.

NOTICE:
·

To avoid damaging the fins, the injection direction should be at right angles to the core surface.

·

If the steam cleaner is too close to the core, there is a possibility of damaging the fins, so maintain the following injection distances.

Standard Injection Distance:
Injection Pressure Specified Condition
2942 to 4903 kPa (30.0 to 50.0 kgf/cm2, 427 to 711 psi) 300 mm (11.8 in.)
4903 to 7845 kPa (50.0 to 80.0 kgf/cm2, 711 to 1138 psi) 500 mm (19.7 in.)


·

If the fins are bent, straighten them with a screwdriver or pliers.

·

Do not expose electronic components to water.




b.

Dry the fins with compressed air.