28300 1.INSPECT STARTER RELAY (ST)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the starter relay.
28610A 2.INSPECT NO. 1 GLOW PLUG RELAY (GLOW 1)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the No. 1 glow plug relay.
28610A 3.INSPECT NO. 2 GLOW PLUG RELAY (GLOW 2)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the No. 2 glow plug relay.