Home › Engine / Hybrid System › 1VD-FTV (STARTING) › RELAY
RM25T0E _51 Engine / Hybrid System _029900 1VD-FTV STARTING _0137004 RELAY G

1VD-FTV STARTING  RELAY  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 28300 1.INSPECT STARTER RELAY (ST)

a.
A296121N02
2.354,0.792 2.615,0.531 true 2.667,1.115 3.031,1.115 true 2.365,1.427 2.146,1.688 true 1.635,1.104 2,1.104 true 0.302,0.792 0.458,0.99 0.156,0.198 10 3 0.313,1.333 0.469,1.531 0.156,0.198 10 2 1.292,1.313 1.448,1.51 0.156,0.198 10 1 1.302,0.792 1.458,0.99 0.156,0.198 10 5 2.625,0.375 2.781,0.573 0.156,0.198 10 1 3.094,1.042 3.25,1.24 0.156,0.198 10 5 2.083,1.719 2.24,1.917 0.156,0.198 10 2 1.51,1.021 1.667,1.219 0.156,0.198 10 3

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the starter relay.


Hide 28610A 2.INSPECT NO. 1 GLOW PLUG RELAY (GLOW 1)

a.
A296121N03
2.354,0.792 2.615,0.531 true 2.667,1.115 3.031,1.115 true 2.365,1.427 2.146,1.688 true 1.635,1.104 2,1.104 true 0.302,0.792 0.458,0.99 0.156,0.198 10 3 0.313,1.333 0.469,1.531 0.156,0.198 10 2 1.292,1.313 1.448,1.51 0.156,0.198 10 1 1.302,0.792 1.458,0.99 0.156,0.198 10 5 2.625,0.375 2.781,0.573 0.156,0.198 10 1 3.094,1.042 3.25,1.24 0.156,0.198 10 5 2.083,1.719 2.24,1.917 0.156,0.198 10 2 1.51,1.021 1.667,1.219 0.156,0.198 10 3

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the No. 1 glow plug relay.


Hide 28610A 3.INSPECT NO. 2 GLOW PLUG RELAY (GLOW 2)

a.
A296121N03
2.354,0.792 2.615,0.531 true 2.667,1.115 3.031,1.115 true 2.365,1.427 2.146,1.688 true 1.635,1.104 2,1.104 true 0.302,0.792 0.458,0.99 0.156,0.198 10 3 0.313,1.333 0.469,1.531 0.156,0.198 10 2 1.292,1.313 1.448,1.51 0.156,0.198 10 1 1.302,0.792 1.458,0.99 0.156,0.198 10 5 2.625,0.375 2.781,0.573 0.156,0.198 10 1 3.094,1.042 3.25,1.24 0.156,0.198 10 5 2.083,1.719 2.24,1.917 0.156,0.198 10 2 1.51,1.021 1.667,1.219 0.156,0.198 10 3

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the No. 2 glow plug relay.