84820 1.INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (for LHD)
| *1 | Window Lock Switch |
| *2 | Front Power Window LH Switch |
| *3 | Front Power Window RH Switch |
| *4 | Rear Power Window LH Switch |
| *5 | Rear Power Window RH Switch |
| *6 | Door Lock Switch |
| *a | Component without harness connected (Power Window Regulator Master Switch Assembly) |
for Type A:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 6 - 7 | Front power window LH switch UP | Below 1 Ω |
| 6 - 1 | Front power window LH switch DOWN or OFF | Below 1 Ω |
| 6 - 13 | Front power window LH switch OFF | Below 1 Ω |
| 13 - 7 | Front power window LH switch DOWN | Below 1 Ω |
| 13 - 1 | Front power window LH switch UP or OFF | Below 1 Ω |
| 12 - 7 | Front power window RH switch UP | Below 1 Ω |
| 12 - 1 | Window lock switch UNLOCK, front power window RH switch DOWN or OFF | Below 1 Ω |
| Window lock switch LOCK, front power window RH switch DOWN or OFF | 10 kΩ or higher | |
| 5 - 7 | Front power window RH switch DOWN | Below 1 Ω |
| 5 - 1 | Window lock switch UNLOCK, front power window RH switch UP or OFF | Below 1 Ω |
| Window lock switch LOCK, front power window RH switch UP or OFF | 10 kΩ or higher | |
| 12 - 5 | Front power window RH switch OFF | Below 1 Ω |
| 11 - 7 | Rear power window RH switch UP | Below 1 Ω |
| 11 - 1 | Window lock switch UNLOCK, rear power window RH switch DOWN or OFF | Below 1 Ω |
| Window lock switch LOCK, rear power window RH switch DOWN or OFF | 10 kΩ or higher | |
| 14 - 7 | Rear power window RH switch DOWN | Below 1 Ω |
| 14 - 1 | Window lock switch UNLOCK, rear power window RH switch UP or OFF | Below 1 Ω |
| Window lock switch LOCK, rear power window RH switch UP or OFF | 10 kΩ or higher | |
| 11 - 14 | Rear power window RH switch OFF | Below 1 Ω |
| 10 - 7 | Rear power window LH switch UP | Below 1 Ω |
| 10 - 1 | Window lock switch UNLOCK, rear power window LH switch DOWN or OFF | Below 1 Ω |
| Window lock switch LOCK, rear power window LH switch DOWN or OFF | 10 kΩ or higher | |
| 9 - 7 | Rear power window LH switch DOWN | Below 1 Ω |
| 9 - 1 | Window lock switch UNLOCK, rear power window LH switch UP or OFF | Below 1 Ω |
| Window lock switch LOCK, rear power window LH switch UP or OFF | 10 kΩ or higher | |
| 10 - 9 | Rear power window LH switch OFF | Below 1 Ω |
If the result is not as specified, replace the power window regulator master switch assembly.
Check the door lock switch function.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 1 - 4 | Lock | Below 1 Ω |
| 1 - 3 | Unlock | Below 1 Ω |
If the result is not as specified, replace the power window regulator master switch assembly.
| *1 | Window Lock Switch |
| *2 | Front Power Window LH Switch |
| *3 | Front Power Window RH Switch |
| *4 | Door Lock Switch |
| *a | Component without harness connected (Power Window Regulator Master Switch Assembly) |
for Type B:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3 - 9 4 - 6 |
Front power window LH switch UP | Below 1 Ω |
| 3 - 9 4 - 6 |
Window lock switch LOCK, Front power window LH switch UP | Below 1 Ω |
| 3 - 6 4 - 6 |
Front power window LH switch OFF | Below 1 Ω |
| 3 - 6 4 - 6 |
Window lock switch LOCK, Front power window LH switch OFF | Below 1 Ω |
| 4 - 9 3 - 6 |
Front power window LH switch DOWN | Below 1 Ω |
| 4 - 9 3 - 6 |
Window lock switch LOCK, Front power window LH switch DOWN | Below 1 Ω |
| 9 - 10 6 - 7 |
Window lock switch UNLOCK, Front power window RH switch UP | Below 1 Ω |
| 9 - 10 | Window lock switch LOCK, Front power window RH switch UP | Below 1 Ω |
| 6 - 10 6 - 7 |
Window lock switch UNLOCK, Front power window RH switch OFF | Below 1 Ω |
| 7 - 10 | Window lock switch LOCK, Front power window RH switch OFF | Below 1 Ω |
| 7 - 9 6 - 10 |
Window lock switch UNLOCK, front power window RH switch DOWN | Below 1 Ω |
| 7 - 9 | Window lock switch LOCK, front power window RH switch DOWN | Below 1 Ω |
If the result is not as specified, replace the power window regulator master switch assembly.
Check the door lock switch function.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 1 - 5 2 - 6 |
Lock | Below 1 Ω |
| 5 - 6 | Off | 10 kΩ or higher |
| 1 - 6 2 - 5 |
Unlock | Below 1 Ω |
If the result is not as specified, replace the power window regulator master switch assembly.
84820 2.INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (for RHD)
| *1 | Window Lock Switch |
| *2 | Front Power Window LH Switch |
| *3 | Front Power Window RH Switch |
| *4 | Rear Power Window LH Switch |
| *5 | Rear Power Window RH Switch |
| *6 | Door Lock Switch |
| *a | Component without harness connected (Power Window Regulator Master Switch Assembly) |
for Type A:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 1 - 13 | Front power window RH switch UP | Below 1 Ω |
| 1 - 5 | Front power window RH switch DOWN or OFF | Below 1 Ω |
| 1 - 8 | Front power window RH switch OFF | Below 1 Ω |
| 8 - 13 | Front power window RH switch DOWN | Below 1 Ω |
| 8 - 5 | Front power window RH switch UP or OFF | Below 1 Ω |
| 9 - 13 | Front power window LH switch UP | Below 1 Ω |
| 9 - 5 | Window lock switch UNLOCK, front power window LH switch DOWN or OFF | Below 1 Ω |
| Window lock switch LOCK, front power window LH switch DOWN or OFF | 10 kΩ or higher | |
| 2 - 13 | Front power window LH switch DOWN | Below 1 Ω |
| 2 - 5 | Window lock switch UNLOCK, front power window LH switch UP or OFF | Below 1 Ω |
| Window lock switch LOCK, front power window LH switch UP or OFF | 10 kΩ or higher | |
| 9 - 2 | Front power window LH switch OFF | Below 1 Ω |
| 11 - 13 | Rear power window RH switch UP | Below 1 Ω |
| 11 - 5 | Window lock switch UNLOCK, rear power window RH switch DOWN or OFF | Below 1 Ω |
| Window lock switch LOCK, rear power window RH switch DOWN or OFF | 10 kΩ or higher | |
| 12 - 13 | Rear power window RH switch DOWN | Below 1 Ω |
| 12 - 5 | Window lock switch UNLOCK, rear power window RH switch UP or OFF | Below 1 Ω |
| Window lock switch LOCK, rear power window RH switch UP or OFF | 10 kΩ or higher | |
| 11 - 12 | Rear power window RH switch OFF | Below 1 Ω |
| 10 - 13 | Rear power window LH switch UP | Below 1 Ω |
| 10 - 5 | Window lock switch UNLOCK, rear power window LH switch DOWN or OFF | Below 1 Ω |
| Window lock switch LOCK, rear power window LH switch DOWN or OFF | 10 kΩ or higher | |
| 7 - 13 | Rear power window LH switch DOWN | Below 1 Ω |
| 7 - 5 | Window lock switch UNLOCK, rear power window LH switch UP or OFF | Below 1 Ω |
| Window lock switch LOCK, rear power window LH switch UP or OFF | 10 kΩ or higher | |
| 10 - 7 | Rear power window LH switch OFF | Below 1 Ω |
If the result is not as specified, replace the power window regulator master switch assembly.
Check the door lock switch function.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3 - 6 | Lock | Below 1 Ω |
| 4 - 6 | Unlock | Below 1 Ω |
If the result is not as specified, replace the power window regulator master switch assembly.
| *1 | Window Lock Switch |
| *2 | Front Power Window LH Switch |
| *3 | Front Power Window RH Switch |
| *4 | Door Lock Switch |
| *a | Component without harness connected (Power Window Regulator Master Switch Assembly) |
for Type B:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 2 - 6 1 - 8 |
Front power window RH switch UP | Below 1 Ω |
| 2 - 6 1 - 8 |
Window lock switch LOCK, Front power window RH switch UP | Below 1 Ω |
| 1 - 8 2 - 8 |
Front power window RH switch OFF | Below 1 Ω |
| 1 - 8 2 - 8 |
Window lock switch LOCK, Front power window RH switch OFF | Below 1 Ω |
| 1 - 6 2 - 8 |
Front power window RH switch DOWN | Below 1 Ω |
| 1 - 6 2 - 8 |
Window lock switch LOCK, Front power window RH switch DOWN | Below 1 Ω |
| 5 - 6 7 - 8 |
Window lock switch UNLOCK, Front power window LH switch UP | Below 1 Ω |
| 5 - 6 | Window lock switch LOCK, Front power window LH switch UP | Below 1 Ω |
| 5 - 8 7 - 8 |
Window lock switch UNLOCK, Front power window LH switch OFF | Below 1 Ω |
| 5 - 7 | Window lock switch LOCK, Front power window LH switch OFF | Below 1 Ω |
| 6 - 7 5 - 8 |
Window lock switch UNLOCK, front power window LH switch DOWN | Below 1 Ω |
| 6 - 7 | Window lock switch LOCK, front power window LH switch DOWN | Below 1 Ω |
If the result is not as specified, replace the power window regulator master switch assembly.
Check the door lock switch function.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3 - 9 4 - 10 |
Lock | Below 1 Ω |
| 9 - 10 | Off | 10 kΩ or higher |
| 4 - 9 3 - 10 |
Unlock | Below 1 Ω |
If the result is not as specified, replace the power window regulator master switch assembly.