Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW MASTER SWITCH
RM25T0E _59 Vehicle Exterior _029935 WINDOW / GLASS _0137652 POWER WINDOW MASTER SWITCH G

WINDOW / GLASS  POWER WINDOW MASTER SWITCH  INSPECTION  


PROCEDURE

Hide 84820 1.INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (for LHD)

a.
E147679C03
1.354,0.552 1.813,0.552 false 1.938,0.906 2.396,0.906 false 2.531,1.323 2.99,1.323 false 1.031,1.677 2.104,1.677 true 0.479,1.313 1.552,1.313 true 0.438,0.729 0.698,0.729 true 0.74,2.771 1.052,2.927 0.313,0.156 10 false *a 1.844,0.479 2.156,0.635 0.313,0.156 10 false *1 0.302,1.24 0.615,1.396 0.313,0.156 10 false *2 2.438,0.833 2.75,0.99 0.313,0.156 10 false *3 0.896,1.604 1.208,1.76 0.313,0.156 10 false *4 3.021,1.26 3.333,1.417 0.313,0.156 10 false *5 0.229,0.656 0.542,0.854 0.313,0.198 10 false *6
*1 Window Lock Switch
*2 Front Power Window LH Switch
*3 Front Power Window RH Switch
*4 Rear Power Window LH Switch
*5 Rear Power Window RH Switch
*6 Door Lock Switch
*a Component without harness connected
(Power Window Regulator Master Switch Assembly)


for Type A:

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
6 - 7 Front power window LH switch UP Below 1 Ω
6 - 1 Front power window LH switch DOWN or OFF Below 1 Ω
6 - 13 Front power window LH switch OFF Below 1 Ω
13 - 7 Front power window LH switch DOWN Below 1 Ω
13 - 1 Front power window LH switch UP or OFF Below 1 Ω
12 - 7 Front power window RH switch UP Below 1 Ω
12 - 1 Window lock switch UNLOCK, front power window RH switch DOWN or OFF Below 1 Ω
Window lock switch LOCK, front power window RH switch DOWN or OFF 10 kΩ or higher
5 - 7 Front power window RH switch DOWN Below 1 Ω
5 - 1 Window lock switch UNLOCK, front power window RH switch UP or OFF Below 1 Ω
Window lock switch LOCK, front power window RH switch UP or OFF 10 kΩ or higher
12 - 5 Front power window RH switch OFF Below 1 Ω
11 - 7 Rear power window RH switch UP Below 1 Ω
11 - 1 Window lock switch UNLOCK, rear power window RH switch DOWN or OFF Below 1 Ω
Window lock switch LOCK, rear power window RH switch DOWN or OFF 10 kΩ or higher
14 - 7 Rear power window RH switch DOWN Below 1 Ω
14 - 1 Window lock switch UNLOCK, rear power window RH switch UP or OFF Below 1 Ω
Window lock switch LOCK, rear power window RH switch UP or OFF 10 kΩ or higher
11 - 14 Rear power window RH switch OFF Below 1 Ω
10 - 7 Rear power window LH switch UP Below 1 Ω
10 - 1 Window lock switch UNLOCK, rear power window LH switch DOWN or OFF Below 1 Ω
Window lock switch LOCK, rear power window LH switch DOWN or OFF 10 kΩ or higher
9 - 7 Rear power window LH switch DOWN Below 1 Ω
9 - 1 Window lock switch UNLOCK, rear power window LH switch UP or OFF Below 1 Ω
Window lock switch LOCK, rear power window LH switch UP or OFF 10 kΩ or higher
10 - 9 Rear power window LH switch OFF Below 1 Ω


If the result is not as specified, replace the power window regulator master switch assembly.


ii.

Check the door lock switch function.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
1 - 4 Lock Below 1 Ω
1 - 3 Unlock Below 1 Ω


If the result is not as specified, replace the power window regulator master switch assembly.



b.
B387036C02
1.604,0.542 2.073,0.542 false 2.271,0.969 2.74,0.969 false 0.844,1.292 1.781,1.292 true 0.625,0.75 0.958,0.75 true 0.865,2.781 1.177,2.938 0.313,0.156 10 false *a 2.115,0.469 2.427,0.625 0.313,0.156 10 false *1 0.667,1.208 0.979,1.365 0.313,0.156 10 false *2 2.771,0.885 3.083,1.042 0.313,0.156 10 false *3 0.438,0.667 0.75,0.865 0.313,0.198 10 false *4
*1 Window Lock Switch
*2 Front Power Window LH Switch
*3 Front Power Window RH Switch
*4 Door Lock Switch
*a Component without harness connected
(Power Window Regulator Master Switch Assembly)


for Type B:

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
3 - 9
4 - 6
Front power window LH switch UP Below 1 Ω
3 - 9
4 - 6
Window lock switch LOCK, Front power window LH switch UP Below 1 Ω
3 - 6
4 - 6
Front power window LH switch OFF Below 1 Ω
3 - 6
4 - 6
Window lock switch LOCK, Front power window LH switch OFF Below 1 Ω
4 - 9
3 - 6
Front power window LH switch DOWN Below 1 Ω
4 - 9
3 - 6
Window lock switch LOCK, Front power window LH switch DOWN Below 1 Ω
9 - 10
6 - 7
Window lock switch UNLOCK, Front power window RH switch UP Below 1 Ω
9 - 10 Window lock switch LOCK, Front power window RH switch UP Below 1 Ω
6 - 10
6 - 7
Window lock switch UNLOCK, Front power window RH switch OFF Below 1 Ω
7 - 10 Window lock switch LOCK, Front power window RH switch OFF Below 1 Ω
7 - 9
6 - 10
Window lock switch UNLOCK, front power window RH switch DOWN Below 1 Ω
7 - 9 Window lock switch LOCK, front power window RH switch DOWN Below 1 Ω


If the result is not as specified, replace the power window regulator master switch assembly.


ii.

Check the door lock switch function.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
1 - 5
2 - 6
Lock Below 1 Ω
5 - 6 Off 10 kΩ or higher
1 - 6
2 - 5
Unlock Below 1 Ω


If the result is not as specified, replace the power window regulator master switch assembly.



Hide 84820 2.INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (for RHD)

a.
B387035C04
1.49,0.531 2.063,0.531 false 0.865,0.917 1.438,0.917 false 0.292,1.323 0.865,1.323 false 1.229,1.656 2.531,1.656 true 1.792,1.25 3.094,1.25 true 2.677,0.74 3.073,0.74 true 0.677,2.781 0.99,2.938 0.313,0.156 10 false *a 1.313,0.438 1.625,0.594 0.313,0.156 10 false *1 0.698,0.844 1.01,1 0.313,0.156 10 false *2 3.135,1.188 3.354,1.344 0.219,0.156 10 false *3 0.125,1.25 0.438,1.406 0.313,0.156 10 false *4 2.583,1.594 2.896,1.75 0.313,0.156 10 false *5 3.115,0.667 3.375,0.865 0.26,0.198 10 false *6
*1 Window Lock Switch
*2 Front Power Window LH Switch
*3 Front Power Window RH Switch
*4 Rear Power Window LH Switch
*5 Rear Power Window RH Switch
*6 Door Lock Switch
*a Component without harness connected
(Power Window Regulator Master Switch Assembly)


for Type A:

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
1 - 13 Front power window RH switch UP Below 1 Ω
1 - 5 Front power window RH switch DOWN or OFF Below 1 Ω
1 - 8 Front power window RH switch OFF Below 1 Ω
8 - 13 Front power window RH switch DOWN Below 1 Ω
8 - 5 Front power window RH switch UP or OFF Below 1 Ω
9 - 13 Front power window LH switch UP Below 1 Ω
9 - 5 Window lock switch UNLOCK, front power window LH switch DOWN or OFF Below 1 Ω
Window lock switch LOCK, front power window LH switch DOWN or OFF 10 kΩ or higher
2 - 13 Front power window LH switch DOWN Below 1 Ω
2 - 5 Window lock switch UNLOCK, front power window LH switch UP or OFF Below 1 Ω
Window lock switch LOCK, front power window LH switch UP or OFF 10 kΩ or higher
9 - 2 Front power window LH switch OFF Below 1 Ω
11 - 13 Rear power window RH switch UP Below 1 Ω
11 - 5 Window lock switch UNLOCK, rear power window RH switch DOWN or OFF Below 1 Ω
Window lock switch LOCK, rear power window RH switch DOWN or OFF 10 kΩ or higher
12 - 13 Rear power window RH switch DOWN Below 1 Ω
12 - 5 Window lock switch UNLOCK, rear power window RH switch UP or OFF Below 1 Ω
Window lock switch LOCK, rear power window RH switch UP or OFF 10 kΩ or higher
11 - 12 Rear power window RH switch OFF Below 1 Ω
10 - 13 Rear power window LH switch UP Below 1 Ω
10 - 5 Window lock switch UNLOCK, rear power window LH switch DOWN or OFF Below 1 Ω
Window lock switch LOCK, rear power window LH switch DOWN or OFF 10 kΩ or higher
7 - 13 Rear power window LH switch DOWN Below 1 Ω
7 - 5 Window lock switch UNLOCK, rear power window LH switch UP or OFF Below 1 Ω
Window lock switch LOCK, rear power window LH switch UP or OFF 10 kΩ or higher
10 - 7 Rear power window LH switch OFF Below 1 Ω


If the result is not as specified, replace the power window regulator master switch assembly.


ii.

Check the door lock switch function.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
3 - 6 Lock Below 1 Ω
4 - 6 Unlock Below 1 Ω


If the result is not as specified, replace the power window regulator master switch assembly.



b.
B387037C02
1.229,0.563 1.802,0.563 false 0.615,0.958 1.188,0.958 false 1.594,1.25 2.76,1.25 true 2.427,0.75 2.771,0.75 true 0.917,2.917 1.229,3.073 0.313,0.156 10 false *a 1.073,0.49 1.385,0.646 0.313,0.156 10 false *1 0.458,0.885 0.771,1.042 0.313,0.156 10 false *2 2.802,1.188 3.115,1.344 0.313,0.156 10 false *3 2.854,0.688 3.167,0.885 0.313,0.198 10 false *4
*1 Window Lock Switch
*2 Front Power Window LH Switch
*3 Front Power Window RH Switch
*4 Door Lock Switch
*a Component without harness connected
(Power Window Regulator Master Switch Assembly)


for Type B:

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
2 - 6
1 - 8
Front power window RH switch UP Below 1 Ω
2 - 6
1 - 8
Window lock switch LOCK, Front power window RH switch UP Below 1 Ω
1 - 8
2 - 8
Front power window RH switch OFF Below 1 Ω
1 - 8
2 - 8
Window lock switch LOCK, Front power window RH switch OFF Below 1 Ω
1 - 6
2 - 8
Front power window RH switch DOWN Below 1 Ω
1 - 6
2 - 8
Window lock switch LOCK, Front power window RH switch DOWN Below 1 Ω
5 - 6
7 - 8
Window lock switch UNLOCK, Front power window LH switch UP Below 1 Ω
5 - 6 Window lock switch LOCK, Front power window LH switch UP Below 1 Ω
5 - 8
7 - 8
Window lock switch UNLOCK, Front power window LH switch OFF Below 1 Ω
5 - 7 Window lock switch LOCK, Front power window LH switch OFF Below 1 Ω
6 - 7
5 - 8
Window lock switch UNLOCK, front power window LH switch DOWN Below 1 Ω
6 - 7 Window lock switch LOCK, front power window LH switch DOWN Below 1 Ω


If the result is not as specified, replace the power window regulator master switch assembly.


ii.

Check the door lock switch function.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
3 - 9
4 - 10
Lock Below 1 Ω
9 - 10 Off 10 kΩ or higher
4 - 9
3 - 10
Unlock Below 1 Ω


If the result is not as specified, replace the power window regulator master switch assembly.