1.INSPECT COUNTER GEAR
Using a micrometer, measure the journal diameter of the counter gear as shown in the illustration.
| Measuring point | Standard journal diameter | Minimum journal diameter |
|---|---|---|
| A | 30.002 to 30.015 mm (1.1812 to 1.1816 in.) | 30.002 mm (1.1812 in.) |
| B | 35.957 to 35.970 mm (1.4157 to 1.4161 in.) | 35.957 mm (1.4156 in.) |
If the journal diameter is less than the minimum, replace the counter gear with a new one.