Home › Vehicle Interior › HEATING / AIR CONDITIONING › BLOWER RESISTOR
RM25T0E _58 Vehicle Interior _029469 HEATING / AIR CONDITIONING _0137760 BLOWER RESISTOR G

HEATING / AIR CONDITIONING  BLOWER RESISTOR  INSPECTION  


PROCEDURE

Hide 87138C 1.INSPECT BLOWER RESISTOR (for LHD, 12 V Battery)

a.
E258746C02
1.958,1.021 2.25,0.344 true 1.479,1.01 1.177,0.333 true 1.948,1.344 2.25,1.802 true 1.5,1.344 1.188,1.802 true 0.063,0 0.24,0.198 0.177,0.198 10 false *a 1.021,1.802 1.292,2 0.271,0.198 10 false H1 2.281,1.792 2.552,1.99 0.271,0.198 10 false M1 2.24,0.167 2.417,0.354 0.177,0.188 10 false E 1.031,0.156 1.302,0.375 0.271,0.219 10 false M2
*a Component without harness connected
(Blower Resistor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
4 (H1) - 2 (M2) Always 0.39 to 0.45 Ω
4 (H1) - 3 (M1) Always 1.32 to 1.52 Ω
4 (H1) - 1 (E) Always 2.08 to 2.40 Ω


If the result is not as specified, replace the blower resistor.


Hide 87138C 2.INSPECT BLOWER RESISTOR (for RHD, 12 V Battery)

a.
E258746C01
1.958,1.021 2.25,0.344 true 1.479,1.01 1.177,0.333 true 1.948,1.344 2.25,1.802 true 1.5,1.344 1.188,1.802 true 0.063,0 0.24,0.198 0.177,0.198 10 false *a 2.24,0.125 2.51,0.323 0.271,0.198 10 false H1 0.969,0.125 1.24,0.323 0.271,0.198 10 false M1 1.073,1.833 1.25,2.021 0.177,0.188 10 false E 2.24,1.833 2.51,2.052 0.271,0.219 10 false M2
*a Component without harness connected
(Blower Resistor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (H1) - 3 (M2) Always 0.39 to 0.45 Ω
1 (H1) - 2 (M1) Always 1.32 to 1.52 Ω
1 (H1) - 4 (E) Always 2.08 to 2.40 Ω


If the result is not as specified, replace the blower resistor.


Hide 87138C 3.INSPECT BLOWER RESISTOR (for 24 V Battery)

a.
E258746C01
1.958,1.021 2.25,0.344 true 1.479,1.01 1.177,0.333 true 1.948,1.344 2.25,1.802 true 1.5,1.344 1.188,1.802 true 0.063,0 0.24,0.198 0.177,0.198 10 false *a 2.24,0.125 2.51,0.323 0.271,0.198 10 false H1 0.969,0.125 1.24,0.323 0.271,0.198 10 false M1 1.073,1.833 1.25,2.021 0.177,0.188 10 false E 2.24,1.833 2.51,2.052 0.271,0.219 10 false M2
*a Component without harness connected
(Blower Resistor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (H1) - 3 (M2) Always 1.49 to 1.71 Ω
1 (H1) - 2 (M1) Always 5.12 to 5.86 Ω
1 (H1) - 4 (E) Always 8.18 to 9.42 Ω


If the result is not as specified, replace the blower resistor.