Home › Brake › BRAKE SYSTEM (OTHER) › LOAD SENSING PROPORTIONING VALVE
RM25T0E _54 Brake _029916 BRAKE SYSTEM (OTHER) _0138397 LOAD SENSING PROPORTIONING VALVE A

BRAKE SYSTEM (OTHER)  LOAD SENSING PROPORTIONING VALVE  REMOVAL  


PROCEDURE

Hide 1.DRAIN BRAKE FLUID

NOTICE:

Wash off brake fluid immediately if it comes in contact with any painted surface.


Hide 2.DISCONNECT BRAKE TUBE

a.
C315351

Using a union nut wrench, disconnect the 3 brake tubes from the valve body.


Hide 3.REMOVE LOAD SENSING PROPORTIONING VALVE ASSEMBLY

a.
C210995

Remove the 2 bolts from the No. 1 load sensing shackle bracket.


b.
C315352

Remove the 4 bolts and load sensing proportioning valve.


Hide 47932A 4.REMOVE LOAD SENSING VALVE UNION BRACKET

a.
C315353

Remove the 4 bolts and bracket.