Home › Drivetrain › AXLE AND DIFFERENTIAL › FRONT DIFFERENTIAL LOCK ACTUATOR(w/ Differential Lock)
RM25T0E _52 Drivetrain _029907 AXLE AND DIFFERENTIAL _0137470 FRONT DIFFERENTIAL LOCK ACTUATOR(w/ Differential Lock) G

AXLE AND DIFFERENTIAL  FRONT DIFFERENTIAL LOCK ACTUATOR(w/ Differential Lock)  INSPECTION  


PROCEDURE

Hide 41450A 1.INSPECT NO. 2 DIFFERENTIAL LOCK SHIFT ACTUATOR

a.

Check the free to lock switch.

i.

Connect lines via a relay as shown in the illustration, and check that the actuator moves from the free to lock position.

NOTICE:
·

Make sure to perform this inspection with the actuator removed from the vehicle. If this inspection is performed with the actuator installed to the vehicle, the actuator will be damaged.

·

When inspecting the actuator, make sure to operate it with the lines connected via a relay. If the lines are not connected via a relay and battery voltage is directly applied to the actuator, the actuator will be damaged.



HINT:

When performing the operation described above, use the HTR relay.


C312629C01
5.333,2.948 5.583,2.948 5.583,2.948 5.917,3.198 false 4.958,3.396 5.208,3.396 5.208,3.396 5.542,3.563 false 5.417,4.25 5.667,4.25 5.667,4.25 5.917,4 false 6.75,2.917 6.51,2.917 6.51,2.917 6.104,3.583 false 6.438,3.583 6.615,3.583 6.615,3.583 6.781,3.583 false 1.875,4 1.635,4 1.635,4 1.479,4.333 false 0.938,4 1.021,4 1.021,4 1.104,4.333 false 0.917,5.021 1,5.021 1,5.021 1.146,4.688 false 1.833,5.01 1.75,5.01 1.75,5.01 1.667,4.677 false 1.667,5.354 1.5,5.354 1.5,5.354 1.417,4.688 false 0.302,0.229 0.615,0.427 0.313,0.198 10 false *a 1.25,0.948 1.563,1.146 0.313,0.198 10 false *b 5.875,2.729 6.188,2.927 0.313,0.198 10 false *c 5.188,2.854 5.5,3.052 0.313,0.198 10 false 1 4.813,3.313 5.125,3.51 0.313,0.198 10 false 3 5.292,4.167 5.604,4.365 0.313,0.198 10 false 2 6.813,2.823 7.125,3.021 0.313,0.198 10 false 4 6.823,3.5 7.135,3.698 0.313,0.198 10 false 5 1.948,3.927 2.26,4.125 0.313,0.198 10 false M4 0.688,3.917 1,4.115 0.313,0.198 10 false M3 0.542,4.938 1.042,5.135 0.5,0.198 10 false RLY3 1.927,4.927 2.427,5.125 0.5,0.198 10 false GND 1.729,5.271 2.229,5.469 0.5,0.198 10 false RLY4
*a Component without harness connected
(No. 2 Differential Lock Shift Actuator)
*b Free → Lock
*c HTR Relay - -



ii.

After the free to lock switch is complete, check the limit switch of the No. 2 differential lock shift actuator.

Standard Resistance:
Tester Connection Condition Specified Condition
5 (RLY4) - 4 (GND) After free to lock switch is complete Below 12.5 Ω
6 (RLY3) - 4 (GND) After free to lock switch is complete 500 kΩ or higher


If the result is not as specified, replace the No. 2 differential lock shift actuator.



b.

Check the lock to free switch.

i.

Connect lines via a relay as shown in the illustration, and check that the actuator moves from the lock to free position.

NOTICE:
·

Make sure to perform this inspection with the actuator removed from the vehicle. If this inspection is performed with the actuator installed to the vehicle, the actuator will be damaged.

·

When inspecting the actuator, make sure to operate it with the lines connected via a relay. If the lines are not connected via a relay and battery voltage is directly applied to the actuator, the actuator will be damaged.



HINT:

When performing the operation described above, use the HTR relay.


C312630C01
5.969,3.135 5.719,2.885 5.719,2.885 5.552,2.885 false 5.677,3.49 5.427,3.24 5.427,3.24 5.26,3.24 false 6.01,3.938 5.677,4.188 5.677,4.188 5.51,4.188 false 6.208,3.51 6.458,2.927 6.458,2.927 6.708,2.927 false 6.792,3.521 6.625,3.521 6.625,3.521 6.542,3.521 false 1.573,4.26 1.74,3.927 1.74,3.927 1.906,3.927 false 1.188,4.271 1.021,3.938 1.021,3.938 0.854,3.938 false 1.813,4.625 1.979,4.875 1.979,4.875 2.146,4.875 false 1.583,4.635 1.833,5.219 1.833,5.219 2,5.219 false 1.271,4.635 1.104,4.885 1.104,4.885 0.938,4.885 false 0.167,0.115 0.479,0.313 0.313,0.198 10 false *a 1.385,0.875 1.698,1.073 0.313,0.198 10 false *b 5.979,2.49 6.292,2.688 0.313,0.198 10 false *c 5.427,2.802 5.74,3 0.313,0.198 10 false 1 5.125,3.156 5.438,3.354 0.313,0.198 10 false 3 5.396,4.104 5.708,4.302 0.313,0.198 10 false 2 6.771,2.844 7.083,3.042 0.313,0.198 10 false 4 6.854,3.448 7.094,3.667 0.24,0.219 10 false 5 1.969,3.844 2.281,4.042 0.313,0.198 10 false M4 0.615,3.854 0.927,4.052 0.313,0.198 10 false M3 2.208,4.792 2.625,4.99 0.417,0.198 10 false GND 2.052,5.146 2.635,5.313 0.583,0.167 10 false RLY4 0.563,4.802 1.146,4.969 0.583,0.167 10 false RLY3
*a Component without harness connected
(No. 2 Differential Lock Shift Actuator)
*b Lock → Free
*c HTR Relay - -



ii.

After the free to lock switch is complete, check the limit switch of the No. 2 differential lock shift actuator.

Standard Resistance:
Tester Connection Condition Specified Condition
5 (RLY4) - 4 (GND) After free to lock switch is complete 500 kΩ or higher
6 (RLY3) - 4 (GND) After free to lock switch is complete Below 12.5 Ω


If the result is not as specified, replace the No. 2 differential lock shift actuator.