41450A 1.INSPECT NO. 2 DIFFERENTIAL LOCK SHIFT ACTUATOR
Check the free to lock switch.
Connect lines via a relay as shown in the illustration, and check that the actuator moves from the free to lock position.
Make sure to perform this inspection with the actuator removed from the vehicle. If this inspection is performed with the actuator installed to the vehicle, the actuator will be damaged.
When inspecting the actuator, make sure to operate it with the lines connected via a relay. If the lines are not connected via a relay and battery voltage is directly applied to the actuator, the actuator will be damaged.
When performing the operation described above, use the HTR relay.
| *a | Component without harness connected (No. 2 Differential Lock Shift Actuator) |
*b | Free → Lock |
| *c | HTR Relay | - | - |
After the free to lock switch is complete, check the limit switch of the No. 2 differential lock shift actuator.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (RLY4) - 4 (GND) | After free to lock switch is complete | Below 12.5 Ω |
| 6 (RLY3) - 4 (GND) | After free to lock switch is complete | 500 kΩ or higher |
If the result is not as specified, replace the No. 2 differential lock shift actuator.
Check the lock to free switch.
Connect lines via a relay as shown in the illustration, and check that the actuator moves from the lock to free position.
Make sure to perform this inspection with the actuator removed from the vehicle. If this inspection is performed with the actuator installed to the vehicle, the actuator will be damaged.
When inspecting the actuator, make sure to operate it with the lines connected via a relay. If the lines are not connected via a relay and battery voltage is directly applied to the actuator, the actuator will be damaged.
When performing the operation described above, use the HTR relay.
| *a | Component without harness connected (No. 2 Differential Lock Shift Actuator) |
*b | Lock → Free |
| *c | HTR Relay | - | - |
After the free to lock switch is complete, check the limit switch of the No. 2 differential lock shift actuator.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (RLY4) - 4 (GND) | After free to lock switch is complete | 500 kΩ or higher |
| 6 (RLY3) - 4 (GND) | After free to lock switch is complete | Below 12.5 Ω |
If the result is not as specified, replace the No. 2 differential lock shift actuator.