85940 1.INSPECT OUT WIPER RELAY 1 (for Canvas Top)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage not applied to terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | 10 kΩ or higher | |
| 3 - 4 | Battery voltage applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Below 1 Ω |
If the result is not as specified, replace the relay.
85940D 2.INSPECT OUT WIPER RELAY 2 (for Canvas Top)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the relay.
85948 3.INSPECT WINDSHIELD WIPER RELAY (for 24 V Battery)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage not applied to terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | 10 kΩ or higher | |
| 3 - 4 | Battery voltage applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Below 1 Ω |
If the result is not as specified, replace the relay.
85941 4.INSPECT WINDSHIELD WASHER RELAY (for 24 V Battery)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the relay.