TERMINALS OF ECU
| *a | Component without harness connected (Skid Control ECU [Brake Actuator Assembly]) |
- | - |
| Terminal No. (Symbol) | Terminal Description |
|---|---|
| 1 (GND2) | Pump motor ground |
| 2 | - (Not used) |
| 3 (EXI) | 4WD position switch (No. 1 transfer indicator switch) input |
| 4 | - (Not used) |
| 5 (EXI4) | L4 position switch (No. 1 transfer indicator switch) input |
| 6 | - (Not used) |
| 7 | - (Not used) |
| 8 | - (Not used) |
| 9 | - (Not used) |
| 10 (CANL) | CAN communication line L |
| 11 (EXI3)* | Rear differential lock position switch (No. 4 transfer indicator switch) signal input |
| 12 (IG1) | ECU power supply input |
| 13 (BM) | Motor relay power supply |
| 14 (SP1) | Speed signal output for speedometer |
| 15 (RR-) | Rear wheel speed RH (-) signal input |
| 16 (RR+) | Rear wheel speed RH (+) power supply output |
| 17 (FL-) | Front wheel speed LH (-) signal input |
| 18 (FL+) | Front wheel speed LH (+) power supply output |
| 19 | - (Not used) |
| 20 | - (Not used) |
| 21 | - (Not used) |
| 22 (CANH) | CAN communication line H |
| 23 (FSW+)* | Pull up terminal for rear differential lock position switch (No. 4 transfer indicator switch) |
| 24 (TS) | Sensor check input |
| 25 (GND1) | Skid control ECU (Brake actuator assembly) ground |
| 26 | - (Not used) |
| 27 (HDCS) | Pull up terminal for L4 position switch (No. 1 transfer indicator switch) |
| 28 (RL-) | Rear wheel speed LH (-) signal input |
| 29 (RL+) | Rear wheel speed LH (+) power supply output |
| 30 (FR-) | Front wheel speed RH (-) signal input |
| 31 (FR+) | Front wheel speed RH (+) power supply output |
| 32 | - (Not used) |
| 33 (CSW) | VSC OFF switch input |
| 34 | - (Not used) |
| 35 (STP) | Stop light switch assembly input |
| 36 | - (Not used) |
| 37 | - (Not used) |
| 38 (+BS) | Solenoid relay power supply |
*: w/ Rear Differential Lock
TERMINAL INSPECTION
Disconnect the A42 connector and measure the voltage or resistance on the wire harness side.
| *a | Front view of wire harness connector (to Skid Control ECU [Brake Actuator Assembly]) |
- | - |
Voltage cannot be measured with the connector connected to the skid control (brake actuator assembly) as the connector is watertight.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| A42-1 (GND2) - Body ground | W-B - Body ground | Pump motor ground | Always | Below 1 Ω |
| A42-3 (EXI) - Body ground | R-Y - Body ground | 4WD position switch (No. 1 transfer indicator switch) input |
·
Ignition switch ON
·
Transfer shifted to H2 |
11 to 14 V |
| A42-5 (EXI4) - Body ground | B-Y - Body ground | L4 position switch (No. 1 transfer indicator switch) input |
·
Ignition switch ON
·
Transfer shifted to L4 |
Below 1 Ω |
| A42-11 (EXI3) - Body ground* | R-L - Body ground | Rear differential lock position switch (No. 4 transfer indicator switch) signal input |
·
Ignition switch ON
·
Rear differential switch ON |
Below 1 Ω |
| A42-12 (IG1) - Body ground | B-Y - Body ground | ECU power supply input | Ignition switch ON | 11 to 14 V |
| A42-13 (BM) - Body ground | W - Body ground | Motor relay power supply | Always | 11 to 14 V |
| A42-14 (SP1) - Body ground | G-R - Body ground | Speed signal output for speedometer | Ignition switch ON | 11 to 14 V |
| A42-23 (FSW+) - Body ground* | R-Y - Body ground | Pull up circuit |
·
Ignition switch ON
·
Rear differential switch ON |
Below 1 Ω |
| A42-25 (GND1) - Body ground | W-B - Body ground | Skid control ECU (Brake actuator assembly) ground | Always | Below 1 Ω |
| A42-27 (HDCS) - Body ground | B-Y - Body ground | Pull up circuit |
·
Ignition switch ON
·
Transfer shifted to L4 |
Below 1 Ω |
| A42-33 (CSW) - Body ground | W - Body ground | VSC OFF switch input | VSC OFF switch pressed and held → released | Below 1 Ω → 10 kΩ or higher |
| A42-35 (STP) - Body ground | W - Body ground | Stop light switch assembly input | Stop light switch assembly on → off (Brake pedal depressed → released) |
8 to 14 V → Below 1.5 V |
| A42-38 (+BS) - Body ground | R - Body ground | Solenoid relay power supply | Always | 11 to 14 V |
*: w/ Rear Differential Lock