23820A 1.INSPECT COMMON RAIL ASSEMBLY LH
Inspect the pressure discharge valve.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 0.96 to 1.16 Ω |
If the result is not as specified, replace the common rail assembly LH.
23810A 2.INSPECT COMMON RAIL ASSEMBLY RH
Inspect the fuel pressure sensor.
| *a | Component without harness connected (Fuel Pressure Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 25°C (77°F) | 16.4 kΩ or less |
| 2 - 3 | 25°C (77°F) | 3 kΩ or less |
If the result is not as specified, replace the common rail RH.