Home › Engine / Hybrid System › 1GR-FE (ENGINE CONTROL) › HEATED OXYGEN SENSOR › from 2021.12
RM25T0E _51 Engine / Hybrid System _029758 1GR-FE ENGINE CONTROL _0135342 HEATED OXYGEN SENSOR G

1GR-FE ENGINE CONTROL  HEATED OXYGEN SENSOR  INSPECTION  


PROCEDURE

Hide 89465 1.INSPECT HEATED OXYGEN SENSOR

a.
A503544C01
1.083,3.25 1.385,3.51 true 1.083,4.167 1.385,4.042 true 2.031,3.5 2.333,3.25 true 0.323,0.333 0.635,0.531 0.313,0.198 10 false *A 1.958,0.333 2.271,0.531 0.313,0.198 10 false *B 0.094,3.094 0.406,3.292 0.313,0.198 10 false *a 0.844,3.156 1.156,3.354 0.313,0.198 10 false +B 0.854,4.094 1.167,4.292 0.313,0.198 10 false E2 2.396,3.156 3.135,3.365 0.74,0.208 10 false HT1B*C 2.396,3.365 3.135,3.573 0.74,0.208 10 false HT2B*D
*A for Type A
*B for Type B
*C for Bank 1
*D for Bank 2
*a Component without harness connected
(Heated Oxygen Sensor)


Measure the resistance according to the value(s) in the table below.

i.

for Type A:

Standard Resistance (for Bank 1):
Tester Connection Condition Specified Condition
1 (HT1B) - 2 (+B) 20°C (68°F) 5 to 10 Ω
1 (HT1B) - 4 (E2) Always 10 kΩ or higher


Standard Resistance (for Bank 2):
Tester Connection Condition Specified Condition
1 (HT2B) - 2 (+B) 20°C (68°F) 5 to 10 Ω
1 (HT2B) - 4 (E2) Always 10 kΩ or higher


If the result is not as specified, replace the heated oxygen sensor.


ii.

for Type B:

Standard Resistance (for Bank 1):
Tester Connection Condition Specified Condition
1 (HT1B) - 2 (+B) 20°C (68°F) 11 to 16 Ω
1 (HT1B) - 4 (E2) Always 10 kΩ or higher


Standard Resistance (for Bank 2):
Tester Connection Condition Specified Condition
1 (HT2B) - 2 (+B) 20°C (68°F) 11 to 16 Ω
1 (HT2B) - 4 (E2) Always 10 kΩ or higher