22204 1.INSPECT MASS AIR FLOW METER
Check the output voltage.
| *a | Component without harness connected (Mass Air Flow Meter) |
|
Air |
Connect a battery positive (+) lead to terminal 3 (+B) and negative (-) lead to terminal 2 (E2G).
While using the battery during inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
Connect the positive (+) tester probe to terminal 1 (VG) and negative (-) tester probe to terminal 2 (E2G).
Blow air into the mass air flow meter and check that the voltage fluctuates.
The voltage changes.
If the result is not as specified, replace the mass air flow meter.
| *a | Component without harness connected (Mass Air Flow Meter) |
Check the intake air temperature sensor (thermistor) resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (THA) - 5 (E2) | Always | 0.48 to 17.7 kΩ |
If the result is not as specified, replace the mass air flow meter.