Home › Power Source / Network › 1HZ (BATTERY / CHARGING) › GENERATOR › from 2022.09
RM25T0E _57 Power Source / Network _029611 1HZ BATTERY / CHARGING _0134068 GENERATOR A

1HZ BATTERY / CHARGING  GENERATOR  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) battery terminal.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 28800 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

Hide 88310A 3.REMOVE NO. 1 V BELT (w/ Air Conditioning System)

Hide 16361A 4.REMOVE FAN AND GENERATOR V BELT

Hide 27020 5.REMOVE GENERATOR ASSEMBLY

a.
A327441

Remove the terminal cap.


b.

Remove the nut and disconnect the generator wire from terminal B.


c.

Disconnect the generator connector.


d.
A327442

Detach the 2 wire harness clamps.


e.
A327443

Remove the 2 bolts and generator assembly.