РЕЛЕ > ПРОВЕРКА БЕЗ СНЯТИЯ С АВТОМОБИЛЯ

для подготовки Нажмите здесь



1. INSPECT STARTER RELAY (ST)


    A0097X9E53
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage not applied to terminals 1 and 2
    10 kΩ or higher
    Battery voltage applied to terminals 1 and 2
    Below 1 Ω

    If the result is not as specified, replace the starter relay.



2. INSPECT GLOW RELAY


    A0097X9E53
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage not applied to terminals 1 and 2
    10 kΩ or higher
    Battery voltage applied to terminals 1 and 2
    Below 1 Ω

    If the result is not as specified, replace the glow relay.