Home › General › INTRODUCTION › WORK NOTICES AND PRECAUTIONS
BM37H0E _V1 General _096507 INTRODUCTION _0453146 WORK NOTICES AND PRECAUTIONS F

INTRODUCTION  WORK NOTICES AND PRECAUTIONS  ENSURING SAFETY AND QUALITY DURING BODY REPAIR OF FUEL CELL VEHICLE  


When repairing the body panels, the same procedures are used as for conventional vehicles. However, when performing work that involves the removal and installation of exclusive parts, such as the hydrogen tanks, hydrogen tank tubes and fuel cell, or performing work in the areas around these parts, there are special precautions unique to FCV that must be taken. Perform work safely by always following the procedures described in this manual, the owner's manual and the electronic technical manual (repair manual).

MAIN PARTS AND PRECAUTIONS FOR FCV


Characteristics and Precautions by System (○: Applicable)
Main Parts Hydrogen-related FC Cooling System Intake System FC converter power outlet cable
1. FC Radiator Characteristics:
·

Hydrogen gas

·

High-pressure gas

·

Fiber-reinforced plastic tank

·

Precision parts


↓
Precautions:
·

Hydrogen safety

·

High-pressure safety

·

Preserving air tightness

·

Entry of foreign matter


○ Characteristics:
·

Exclusive coolant (FCC)

·

Non-reusable parts

·

Precision parts


↓
Precautions:
·

Incorrect addition of fluid

·

Non-reusable parts

·

Entry of foreign matter


The motor system uses conventional LLC (2 types of coolant)
Characteristics:
·

Precision parts


↓
Precautions:
·

Entry of foreign matter


Characteristics:
·

High-voltage

·

Precision parts

·

1 service plug grip

·

FC converter power outlet cable


↓
Precautions:
·

High-voltage safety


2. Cooling Water Pipes ○
3. FC Cooling Water Pump ○ ○
4. FC Cooling Water Ion Exchanger ○
5. Air Cleaner ○
6. FC Air Compressor ○ ○
7. Intercooler ○
8. Inverter / Converter ○
9. EV Transaxle ○
10. FC Stack ○ ○ ○ ○
11. High-voltage Frame Wire ○
12. Hydrogen Pump ○ ○
13. EV Battery ○
14. Hydrogen Tank ○
15. Hydrogen Tank Tubes / Hydrogen Supply Regulator ○
16. Hydrogen Inlet Receptacle ○


MAIN PRECAUTIONS FOR BODY REPAIR


Procedures Precautions
Welding or cutting (sparks or cutting fragments) Do not allow sparks or hot fragments from cutting to contact the hydrogen tanks, hydrogen tank tubes , etc.
Applying paint, putty, etc. (solvents) Do not allow solvents to contact the hydrogen tanks, etc.
Sanding (dust) Do not allow dust or mist to enter the hydrogen, cooling or intake systems.
Applying paint or anti-corrosive coating (mist)
Drying paint or putty (heat) Do not place a far infrared panel near the hydrogen tanks or hydrogen tank tubes (to prevent abnormal temperature increases).
As with other vehicles (other fuel types), a painting booth can only be used when there are no leaks.


SPECIAL PRECAUTIONS FOR BODY REPAIR UNIQUE TO FCV


a.

Working with hydrogen

Parts Location
K162065C04
1.417,2.5 0.917,0.417 0.917,0.417 0.75,0.417 true 4.5,1.75 3.917,0.333 3.917,0.333 3.75,0.333 true 6,2.167 5.75,0.333 5.75,0.333 5.583,0.333 true 3.417,2.5 2.667,0.5 2.667,0.5 2.5,0.5 true 2.156,2.844 2.5,4.25 2.5,4.25 2.667,4.25 true 4.781,3.063 5.083,4.417 5.083,4.417 5.25,4.417 true 5.583,3.5 6.083,4.167 6.083,4.167 6.25,4.167 true 5.417,2.792 5.083,0.75 5.083,0.75 4.917,0.75 true 0.573,0.333 0.885,0.49 0.313,0.156 10 false *1 3.563,0.26 3.875,0.417 0.313,0.156 10 false *3 5.396,0.25 5.708,0.406 0.313,0.156 10 false *3 4.729,0.656 5.042,0.813 0.313,0.156 10 false *4 6.333,4.083 6.646,4.24 0.313,0.156 10 false *5 2.323,0.427 2.635,0.583 0.313,0.156 10 false *3 5.333,4.344 5.646,4.5 0.313,0.156 10 false *2 2.75,4.167 3.063,4.323 0.313,0.156 10 false *4
*1 FC Stack *2 Hydrogen Supply Regulator
*3 Hydrogen Tank *4 Hydrogen Tank Tubes
*5 Hydrogen Inlet Receptacle - -


NOTICE:

When installing a hydrogen tank tube, always use the tank removal and installation guide tool to align the connections.


HINT:

The following are examples of procedures that are often performed.

·

Replacements or repairs including the left quarter panel (wheel house)

·

Replacement or repair of the lower back panel or rear floor panel



○: Performed (○): Performed according to damage or part to be repaired
Vehicle Brought to Workshop Estimation Waiting for Repairs Disassembly Body Repair Vehicle Restoration Final Inspection
Overall *1 Ensure ventilation in the workplace ○ ○ ○ ○ ○ ○ ○
*2 Check for leaks at connections and damaged areas
·

Use a hydrogen gas detector


○ (○) (○) (○) (○) ○
*3 Check for leaks after repairs
·

First inspection: Check for leaks using a 10 MPa nitrogen gas injector

·

Second inspection: Check for leaks with hydrogen at 70 MPa (refuel at a hydrogen station)


(○) (○)
*4 Inspect with a hydrogen detector
·

Perform an inspection using hydrogen gas for inspection (specialized gas)


(○) (○)
Hydrogen Tank *5 Do not allow sparks or solvents to contact the hydrogen tank because it is made of plastic ○ ○ ○
*6 Do not expose the hydrogen tank to high temperatures (85°C or above) ○
*7 Shut off hydrogen using the manual valve (○) (○) (○) (○) (○) (○)
*8 Use the "tank removal and installation guide tool" ○ ○
*9 Gas releasing procedure when disposing of hydrogen tanks (Gradually discharge using a hydrogen discharging device (medium pressure)) ○
Hydrogen Tank Tubes *10 Release pressure before removal because the hydrogen tank tube is under high pressure
·

Release pressure from the medium pressure leak check port of the regulator (vehicle part)


○
*11 Prevent the entry of foreign matter during installation and removal
·

In order to prevent the entry of foreign matter, cover removed parts with a new plastic bag, etc.


○ ○ ○
*12 Do not reuse the high-pressure pipe ○
*13 Use the special jig to install the inlet receptacle and piping ○ ○
*14 Use the "tank removal and installation guide tool" when connecting the hydrogen tank tube to align the connections ○

K162066N01
4.521,0.135 6.719,3.229 2.198,3.094 0.208,0.177 3.813,3.229 3.604,3.052 0.198,3.438 6.74,5.552 6.542,2.115 0.26,0.24 0.573,0.438 0.313,0.198 10 false *1 4.583,0.229 4.896,0.427 0.313,0.198 10 false *2 0.26,3.521 0.573,3.719 0.313,0.198 10 false *3

K162067N01
3.75,0.167 7,4.427 3.25,4.26 0.177,0.167 3.427,4.427 3.25,4.26 0.271,0.25 0.583,0.448 0.313,0.198 10 false *4 3.844,0.25 4.156,0.448 0.313,0.198 10 false *7

K162068N03
0.052,0.25 7.115,3.25 7.063,3 0.052,3.417 2.833,5.667 2.781,2.25 3,3.417 4.917,5.667 1.917,2.25 5.094,3.417 7.01,5.667 1.917,2.25 0.167,0.333 0.417,0.49 0.25,0.156 10 false *8 0.135,3.5 0.448,3.698 0.313,0.198 10 false *9 3.083,3.5 3.396,3.698 0.313,0.198 10 false *10 5.167,3.5 5.479,3.698 0.313,0.198 10 false *11


b.

Working with high voltage

Parts Location
K162069C03
1.313,2.531 0.75,0.583 0.75,0.583 0.583,0.583 true 1.417,2.25 1.25,0.333 1.25,0.333 1.083,0.333 true 1.677,1.938 1.917,0.583 1.917,0.583 2.083,0.583 true 1.667,2.5 2.167,0.833 2.167,0.833 2.333,0.833 true 3.052,2.302 3.583,0.5 3.583,0.5 3.75,0.5 true 5.24,2.344 5.75,0.5 5.75,0.5 5.917,0.5 true 5,2.667 5.583,4.333 5.583,4.333 5.75,4.333 true 5.49,2.427 6.167,0.917 6.167,0.917 6.333,0.917 true 2.333,2.479 3.333,4.083 3.333,4.083 3.5,4.083 true 2.167,3.146 3.083,4.5 3.083,4.5 3.25,4.5 true 1.75,2.75 2.333,4.5 2.333,4.5 2.5,4.5 true 1.521,2.74 1.083,4.583 1.083,4.583 0.917,4.583 true 1.458,2.823 0.833,4.167 0.833,4.167 0.667,4.167 true 1.271,2.792 0.583,3.75 0.583,3.75 0.417,3.75 true 3.333,4.427 3.646,4.583 0.313,0.156 10 false *1 5.844,4.26 6.156,4.417 0.313,0.156 10 false *2 0.229,3.688 0.542,3.844 0.313,0.156 10 false *3 0.49,4.094 0.802,4.25 0.313,0.156 10 false *4 2.167,0.5 2.479,0.656 0.313,0.156 10 false *5 2.417,0.75 2.729,0.906 0.313,0.156 10 false *6 3.583,4.021 3.896,4.177 0.313,0.156 10 false *7 0.896,0.26 1.208,0.417 0.313,0.156 10 false *8 0.385,0.5 0.698,0.656 0.313,0.156 10 false *9 6.417,0.844 6.885,1 0.469,0.156 10 false *10 0.656,4.51 1.125,4.667 0.469,0.156 10 false *11 6,0.438 6.469,0.594 0.469,0.156 10 false *12 2.594,4.427 3.063,4.583 0.469,0.156 10 false *13 3.833,0.438 4.146,0.594 0.313,0.156 10 false *7
*1 Inverter With Converter Assembly *2 FCV W/Motor Transaxle
*3 W/Motor Compressor Cooler Compressor *4 FC Air Compressor
*5 FC Cooling Water Pump *6 Electric Heater
*7 High-voltage Frame Wire *8 FC Converter
*9 FC Stack *10 EV Battery
*11 FC Converter Power Outlet Cable *12 Service Plug Grip
*13 Hydrogen Recirculation Pump Assembly - -


HINT:

The following are examples of procedures that are often performed.

·

Front: Body repair around the power control unit, FC stack or FC Converter

·

Rear: Body repair around the EV battery or FCV transaxle with motor assembly



○: Performed (○): Performed according to damage or part to be repaired
Vehicle Brought to Workshop Estimation Waiting for Repairs Disassembly Body Repair Vehicle Restoration Final Inspection
*1 Removal of the service plug grips
·

This procedure is basically the same as for hybrid vehicles, but make sure to remove 1 service plug grip and the FC converter power outlet cable


(○) (○) ○ ○ ○


c.

Working with FC cooling systems

Parts Location
K162070C03
0.948,2.333 0.5,0.917 0.5,0.917 0.333,0.917 true 1.083,2.167 1.333,0.417 1.333,0.417 1.5,0.417 true 1.281,2.156 2.083,0.5 2.083,0.5 2.25,0.5 true 1.719,2.042 2.583,0.667 2.583,0.667 2.75,0.667 true 2.042,2.031 2.917,0.917 2.917,0.917 3.083,0.917 true 1,2.75 1.167,4.25 1.167,4.25 1.333,4.25 true 1.313,2.75 1.75,4.333 1.75,4.333 1.917,4.333 true 1.698,2.927 2.417,4.417 2.417,4.417 2.583,4.417 true 1.677,2.563 2.667,4.083 2.667,4.083 2.833,4.083 true 0.146,0.833 0.458,0.99 0.313,0.156 10 false *1 1.417,4.167 1.729,4.323 0.313,0.156 10 false *2 2.01,4.26 2.323,4.417 0.313,0.156 10 false *3 2.833,0.594 3.146,0.75 0.313,0.156 10 false *4 2.917,4 3.229,4.156 0.313,0.156 10 false *5 2.667,4.333 2.979,4.49 0.313,0.156 10 false *6 3.167,0.844 3.479,1 0.313,0.156 10 false *7 1.583,0.344 1.896,0.5 0.313,0.156 10 false *8 2.333,0.417 2.646,0.573 0.313,0.156 10 false *9
*1 EV Radiator *2 FC Radiator
*3 EV Water Pomp *4 FC Cooling Water Pump
*5 Electric Heater *6 FC Cooling Water Temperature Control Valve
*7 FC Stack *8 EV Reserve Tank Assembly
*9 FC Radiator Reserve Tank Assembly - -


HINT:
·

Colorless, clear FCC (Toyota genuine FC stack coolant (Pre-mixed)) with insulating properties is used. (Conventional red LLC is used to cool the motor system.)

·

The following are examples of procedures that are often performed.

-

Body repair around the radiator support

-

Body repair around the front fender apron




○: Performed (○): Performed according to damage or part to be repaired
Vehicle Brought to Workshop Estimation Waiting for Repairs Disassembly Body Repair Vehicle Restoration Final Inspection
*1 To prevent the entry of foreign matter, do not reuse FCC (Toyota genuine FC stack coolant (Pre-mixed) Dispose ○
*2 Do not fill with water, conventional LLC, etc., even in small quantities ○
*3 In order to prevent the entry of foreign matter, cover removed parts with a new plastic bag, etc. (○) ○ ○ ○

K162071N01
0.083,0.083 0.396,0.281 0.313,0.198 10 false *3


d.

Working with FC air systems

Parts Location
K162072C03
1.25,1.75 1.583,0.417 1.583,0.417 1.75,0.417 true 2.177,2.417 3.083,0.5 3.083,0.5 3.25,0.5 true 1.344,2.667 1.75,4.5 1.75,4.5 1.917,4.5 true 2.042,2.781 2.333,4.25 2.333,4.25 2.5,4.25 true 3.833,3 4.25,4.167 4.25,4.167 4.417,4.167 true 1.833,0.333 2.146,0.49 0.313,0.156 10 false *1 2.583,4.167 2.896,4.323 0.313,0.156 10 false *2 2,4.427 2.313,4.583 0.313,0.156 10 false *3 4.5,4.094 4.813,4.25 0.313,0.156 10 false *4 3.333,0.417 3.646,0.573 0.313,0.156 10 false *5
*1 Air Cleaner with Element *2 FC Air Compressor with Motor
*3 FC Stack *4 FC Exhaust Tail Pipe
*5 FC Air Bypass Valve - -


HINT:
·

The following are examples of procedures that are often performed.

-

Body repair around the radiator support

-

Body repair around the front fender apron




○: Performed (○): Performed according to damage or part to be repaired
Vehicle Brought to Workshop Estimation Waiting for Repairs Disassembly Body Repair Vehicle Restoration Final Inspection
*1 In order to prevent the entry of foreign matter, cover removed parts with a new plastic bag, etc. (○) ○ ○ ○
*2 Do not start the vehicle with the air cleaner removed ○ ○

K162073N01
0.031,0.052 0.344,0.25 0.313,0.198 10 false *1