Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW CONTROL SYSTEM
NM37H0E _59 Vehicle Exterior _097336 WINDOW / GLASS _0455712 POWER WINDOW CONTROL SYSTEM CO CONTROL F

WINDOW / GLASS  POWER WINDOW CONTROL SYSTEM  CONTROL  POWER WINDOW CONTROL  


SYSTEM CONTROL


a.

The power window control system has the following functions:

Function Outline

*1: Although this function is disabled by default, the function can be set via the customization function.

Power Up-and-down This function causes the window to open or close while the multiplex network master switch assembly and each door power window regulator switch is being pulled halfway up or pushed halfway down. The window stops as soon as the switch is released.
One-touch Auto Up-and-down The one-touch auto up-and-down function enables the window to be fully opened or closed at a touch of the multiplex network master switch assembly and each door power window regulator switch.
Jam Protection The jam protection function automatically stops the power window and moves it downward if a foreign object gets jammed in the window during one-touch auto up operation or power up operation.
Catch Protection The catch protection function automatically stops the power window if a foreign object gets jammed in the window during one-touch auto down operation or power down.
Soft Stop During an up or down operation of the power window, the power window ECU stops the current to the power window motor just before the door glass is fully closed or opened.
Remote Control The multiplex network master switch assembly can control the up-and-down operation of all door windows.
Window Lock
·

Operation of the 3 passenger window at the power window regulator switch assembly is disabled when the window lock switch is pressed.

·

Even when the window lock switch is pressed, the 3 passenger window can be operated using the multiplex network master switch assembly.


Key Off Operation This function makes it possible to operate the power windows for approximately 43 seconds after the ignition switch is turned off, if front door is not opened.
Key-linked Up-and-down*1 When the electrical key transmitter or card key is not in the interior detection area, the driver door is locked, and the mechanical key in the driver door is turned and maintained in the lock direction for approximately 1.5 seconds or more, the main body ECU activates the power window motors to raise all door windows while the mechanical key is turned. Similarly, when the driver door is unlocked, turning and maintaining the driver door key cylinder in the unlock direction for approximately 1.5 seconds or more will cause all door windows to be lowered.
Transmitter-linked Up-and-down*1 When the certification ECU receives an unlock signal from the transmitter for longer than approximately 3 seconds, the main body ECU controls the power window motors in accordance with the signal to open all door windows. Similarly, when the certification ECU receives a lock signal from the transmitter for longer than approximately 3 seconds, the main body ECU controls the power window motors in accordance with the signal to close all door windows.
Power Window Glass Open Warning When the ignition switch is turned from ON to off and the driver door is opened with the door glass open, the meter buzzer sounds once. Then, a warning message appears on the multi-information display.
Suggestion Function When the wipers are operating with the door glass not fully closed (except during mist or washer operations), a message is displayed on the multi-information display and the windows can be closed all at once.
Customization The on or off setting of some functions can be performed using the Global TechStream (GTS). For details, refer to the Repair Manual.

HINT:

The ECU built into each power window motor stores the initial position of its door window. The initial position is not cleared even if the terminals, fuses or the power window motor connector are disconnected. However, after removing or reinstalling window components, or replacing the power window regulator switch assembly or power window regulator motor assembly, the stored initial position data must be cleared and/or initialization must be performed. For details, refer to the Repair Manual.



b.

Jam Protection Function

i.

A jam protection function automatically stops the power window and moves it downward if a foreign object gets jammed in the door window during one-touch auto up operation and power up operation.


ii.

The operation of the jam protection function is described below:

Operation Function
During each door auto up operation and remote control power up/auto up operation Down operation of approximately 145 mm (5.7 in.) or approximately 5 seconds
During each door power up operation Down operation of approximately 45 mm (1.8 in.) or approximately 5 seconds


iii.

The power window ECU determines if a foreign object gets jammed according to changes in the output signal from the pulse sensor (Hall IC). Both of the following 2 judgment methods are used:

Judgment Method (Overload Detection)
Y146728E01
1.177,0.292 3.323,0.49 2.146,0.198 10 false Pulse Signal 1 1.177,0.938 3.323,1.135 2.146,0.198 10 false Pulse Signal 2 4.833,1.313 6.01,1.615 1.177,0.302 10 false Judged Jammed

Judgment Method (Rotation Speed Comparison)
Y146729E01
2.552,0.698 2.552,0.354 2.552,0.354 2.781,0.354 false 4.229,1.573 4.229,1.781 4.229,1.781 4.604,1.781 false 0.458,0.948 1.802,1.427 1.344,0.479 10 false Power Window Motor Rotation Speed 4.469,1.063 5.813,1.542 1.344,0.479 10 false Threshold Value 2.844,0.271 4.188,0.75 1.344,0.479 10 false Jamming Start 4.656,1.698 6,2.177 1.344,0.479 10 false Judged Jammed 2.76,2.25 4.333,2.604 1.573,0.354 10 false Number of Pulse Edges



c.

Catch Protection Function

i.

The catch protection function automatically stops the power window if a foreign object gets caught in the window during a down operation.


ii.

The power window ECU determines if a foreign object gets caught according to changes in the output signal from the pulse sensor (Hall IC). The judgment method is as follows:

Judgment Method (Rotation Speed Comparison)
Y146730E01
2.563,0.688 2.563,0.375 2.563,0.375 2.781,0.375 false 4.698,1.854 4.24,1.854 4.24,1.854 4.24,1.583 false 0.5,0.927 1.833,1.417 1.333,0.49 10 false Power Window Motor Rotation Speed 2.844,0.292 4.177,0.781 1.333,0.49 10 false Catching Start 4.479,1.063 5.813,1.552 1.333,0.49 10 false Threshold Value 4.75,1.76 6.083,2.25 1.333,0.49 10 false Judged Caught 2.708,2.25 4.24,2.594 1.531,0.344 10 false Number of Pulse Edges



d.

Soft Stop Function

i.

During an up operation of the power window, the soft stop function stops the current to the power window motor just before the door glass is fully closed. This reduces the load on the door glass outer weatherstrip.


ii.

Just before the door glass is fully closed, the power window ECU determines if the door glass stop position is detected according to changes in the output signal from the pulse sensor (Hall IC). The judgment method is as follows:

Judgment Method (Rotation Speed Comparison)
Y146731E01
2.552,0.698 2.552,0.385 2.552,0.385 2.781,0.385 false 4.594,1.833 4.24,1.833 4.24,1.833 4.24,1.583 false 0.49,0.969 1.833,1.427 1.344,0.458 10 false Power Window Motor Rotation Speed 2.833,0.292 4.448,0.667 1.615,0.375 10 false Change of Rotation Speed 4.469,1.063 5.656,1.438 1.188,0.375 10 false Threshold Value 4.646,1.74 6.26,2.115 1.615,0.375 10 false Judged Soft Stop 2.677,2.26 4.292,2.635 1.615,0.375 10 false Number of Pulse Edges


iii.

During a down operation of the power window, the power window ECU detects the rotation quantity of the power window motor according to output signals from the pulse sensor (Hall IC), and when the power window reaches the fully open stop position, the power window ECU stops the supply of power to the power window motor.



e.

Suggestion Function

i.

Suggestion to close the power windows

1. When both of the following conditions are met, a suggestion message "Close Windows?" will be displayed on the multi-information display for 6 seconds.

·

Any of the power windows is open.

·

The windshield wipers are operated.*

*: Excludes wiper operations for windshield washer operation or MIST function.


2. When "Yes" is selected using the meter control switches, all open power windows will close.




FAIL-SAFE


a.

If a Hall IC in the power window motor malfunctions, some power window functions will be prohibited in fail-safe mode:

i.

Each power window only operates when the corresponding power window regulator switch is fully pushed down or pulled up and held in that position.


ii.

When any power window ECU detects an abnormality in a Hall IC, which detects the position, speed and direction of the window, it switches to fail-safe mode:




DIAGNOSIS


a.

When the power window ECU detects a malfunction in the power window control system, a Diagnostic Trouble Code (DTC) is stored in memory.

i.

The DTCs can be read using the Global TechStream (GTS). For details, refer to the Repair Manual.