FUNCTION OF MAIN COMPONENTS
| Component | Function |
|---|---|
| EV Control ECU | ·
Detects the electrical load caused by certain electrical components. ·
Calculates the request voltage based on the electrical load caused by certain electrical components and the condition of the auxiliary battery, and sends the request voltage signal to the inverter with converter assembly (DC-DC converter). ·
Restricts the output voltage of the inverter with converter assembly (DC-DC converter). |
| Inverter with Converter Assembly (DC-DC Converter) | Receives the request voltage signal sent from the EV control ECU and restricts the output voltage. |
| Battery State Sensor Assembly | Detects the charge/discharge current, voltage, temperature, SOC (State Of Charge) and self-diagnosis result of the auxiliary battery and sends signals to the EV control ECU. |
| Auxiliary Battery | Supplies power to the electrical components such as the battery cooling blower assembly, water pump with motor assembly, cooling fan motor with controller, etc. and each ECU. |
SYSTEM CONTROL
Basic Control
Controls the output voltage of the inverter with converter assembly (DC-DC converter) in accordance with changes in the target SOC to change the SOC of the auxiliary battery to reduce the power consumption.
Constant Voltage Control
In the following situations, basic control is temporarily suspended and constant voltage control is performed.
A certain period of time has elapsed since the ignition switch is turned on (READY)
In order to compensate for electricity consumed due to parasitic current when the ignition switch is off, constant voltage control is performed for a certain period of time after the ignition switch is turned on (READY).
Stable operation of certain electrical components is required
The state of certain electrical components is monitored, basic control is temporarily canceled and constant voltage control is performed when the system determines that operation of the electrical components may become unstable.
Stable use the auxiliary battery
Constant voltage control is performed and the auxiliary battery is fully charged every 20 driving hours to minimize deterioration of the electrode plates due to sulfation.
Constant voltage control is performed when the SOC of the auxiliary battery is low or the temperature of the auxiliary battery is high/low to minimize deterioration of the auxiliary battery.